Table 6 Cisco AS5350 Compliance Data
Table 7 Cisco AS5350 Environmental Data
Certification Requirements
NEBS Certification • Telcordia SR-3580
• GR-1089-CORE, Issue 2
• GR-63-CORE, Issue 1
• Level 3 certification based on usage and critical nature of equipment
• All equipment CLEI coded
• Available in TIRKS database
Safety Certifications • UL 1950, third edition
• CSA 950, third edition
• EN 60950, with Amendments 1, 2, 3, and 4
• IEC 60950
• AS/NZS 3260
• TS 001
Electromagnetic Emissions
and Immunity Compliance
• EN 55022B (CISPR22)
• EN 300386
• NZS/AS3548 Class B
• VCCI B
• FCC 47CR15 Class B
Environmental Specifications
Heat dissipation 478 Btu/hr (maximum), 389 Bt/hr (typical)
AC power cable supplied with AC systems Single power supply: 18 American wire gauge (AWG), 15-amp
IEC 320 Type C13 standard cable
Redundant power supply: 18 American wire gauge (AWG),
15-amp IEC 320 Type C5 standard cable
DC power cable required for DC systems 12-14 AWG stranded copper wire
Storage temperature 25.8 to 185ºF (-40 to 85ºC)
Acoustics 55 dBA max.; sound pressure level at 1m
Humidity 5 to 95 percent, noncondensing
Altitude -200 to 10,000 ft
Reliability (at 40ºC, 120 VAC and -48VDC, 140W) 7500 FITS per TR-332, (FIT = 1/MTBF)
1.5 x 10
5
hours MTBF per RIN