CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.13 JANUARY 15, 2015 WWW.CISCO.COMSpec SheetCisco UCS B200 M4Blade Ser
Cisco UCS B200 M4 Blade Server10CONFIGURING the SERVERSupported Configurations(1) One-CPU Configuration Choose one CPU from any one of the rows of Ta
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER11STEP 3 CHOOSE MEMORYThe standard memory features are: DIMMs— Clock speed: 2133 MHz— Ranks per D
Cisco UCS B200 M4 Blade Server12CONFIGURING the SERVERChoose DIMMs and Memory MirroringSelect the memory configuration and whether or not you want the
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER13(2) 1-CPU configuration with memory mirroring: Select 2, 4, 8, or 12 identical DIMMs. The DIMMs
Cisco UCS B200 M4 Blade Server14CONFIGURING the SERVER Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page 12.Caveats Syste
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER15— DIMMs with different timing parameters can be installed on different slots within the same cha
Cisco UCS B200 M4 Blade Server16CONFIGURING the SERVERSTEP 4 CHOOSE RAID CONTROLLER AND DISK DRIVE BAYSThe UCS B200 M4 can be ordered with or without
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER17Figure 4 UCS B200 M4 With and Without RAID Controller and Drive Bays (Top View)Figure 5 UCS
Cisco UCS B200 M4 Blade Server18CONFIGURING the SERVERSTEP 5 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES (OPTIONAL)The UCS B200 M4 can be ordered wi
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER19Supported Configurations(1) 1-Drive System Select one of the drives listed in Table 7. (1) 2-Dr
Cisco UCS B200 M4 Blade Server2CONTENTSOVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3DETAIL
Cisco UCS B200 M4 Blade Server20CONFIGURING the SERVERSTEP 6 CHOOSE ADAPTERSThe adapter offerings are: Cisco Virtual Interface Cards (VICs)Cisco deve
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER21NOTE: For environments with 6100 Series Fabric Interconnects, you must configure only the VIC 1
Cisco UCS B200 M4 Blade Server22CONFIGURING the SERVERChoose a Mezzanine AdapterThe supported mezzanine adapters in the UCS B200 M4 are listed in Tabl
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER23Supported ConfigurationsThe supported configurations are listed in Table 9. Choose one configura
Cisco UCS B200 M4 Blade Server24CONFIGURING the SERVERhttp://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.htmlCaveats If a VIC
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER25STEP 7 ORDER TRUSTED PLATFORM MODULE (OPTIONAL)Trusted Platform Module (TPM) is a computer chip
Cisco UCS B200 M4 Blade Server26CONFIGURING the SERVERSTEP 8 ORDER SECURE DIGITAL CARDS (OPTIONAL)Dual SDHC flash card sockets are provided on the fro
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER27STEP 9 ORDER INTERNAL USB 2.0 DRIVE (OPTIONAL)You may order one optional internal USB 2.0 drive.
Cisco UCS B200 M4 Blade Server28CONFIGURING the SERVER NOTE: The figures below show a “peephole” provided on the RAID controller board where you can
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER29STEP 10 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARESeveral operating systems and value-adde
Cisco UCS B200 M4 Blade ServerOVERVIEW3OVERVIEWDelivering performance, versatility and density without compromise, the Cisco UCS B200 M4 Blade Server
Cisco UCS B200 M4 Blade Server30CONFIGURING the SERVERRed Hat Enterprise LinuxRHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs RequiredRHEL-2S-1G-3A RHEL/
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER31VMware 5VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support RqdVMW-VS5-STD
Cisco UCS B200 M4 Blade Server32CONFIGURING the SERVERSTEP 11 CHOOSE OPERATING SYSTEM MEDIA KITChoose the optional operating system media listed in Ta
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER33STEP 12 CHOOSE SERVICE and SUPPORT LEVELA variety of service options are available, as described
Cisco UCS B200 M4 Blade Server34CONFIGURING the SERVERUnified Computing Warranty Plus ServiceFor faster parts replacement than is provided with the st
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER35See Table 17.Partner Support Service for UCS Hardware Only provides customers with replacement p
Cisco UCS B200 M4 Blade Server36CONFIGURING the SERVERYou can choose a service listed in Table 19.Unified Computing Drive Retention ServiceWith the Ci
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER37For more service and support information, see the following URL:http://www.cisco.com/en/US/servi
Cisco UCS B200 M4 Blade Server38CONFIGURING the SERVERORDER OPTIONAL KVM LOCAL I/O CABLE*The KVM local I/O cable ships with every UCS 5100 Series blad
Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL39SUPPLEMENTAL MATERIALSystem BoardA top view of the UCS B200 M4 system board is shown in Figure 7.
Cisco UCS B200 M4 Blade Server4DETAILED VIEWSDETAILED VIEWSBlade Server Front ViewFigure 2 is a detailed front view of the Cisco UCS B200 M4 Blade Ser
Cisco UCS B200 M4 Blade Server40SUPPLEMENTAL MATERIALCPUs and DIMMsPhysical LayoutMemory is organized as shown in Figure 8.Figure 8 UCS B200 M4 Memo
Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL41— Slot 2 - E2, F2, G2, and H2 (black DIMM slots)— Slot 3 - E3, F3, G3, and H3 (white DIMM slots)T
Cisco UCS B200 M4 Blade Server42SUPPLEMENTAL MATERIALDIMM Population OrderPopulate the DIMMs for a CPU according to Table 23. See also Figure 9.Figure
Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL43Recommended Memory ConfigurationThis section explains the recommended DIMM population order rules
Cisco UCS B200 M4 Blade Server44SUPPLEMENTAL MATERIALAdditional DIMM PopulationsThe list in Table 25 is not a complete list of all supported DIMM popu
Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL45Upgrade and Servicing-Related PartsThis section lists the upgrade and servicing-related parts you
Cisco UCS B200 M4 Blade Server46SUPPLEMENTAL MATERIALMotherboard Lithium BatteryYou can order a replacement motherboard battery. Installation instruct
Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL47Network ConnectivityThis section explains how the UCS B200 M4 server connects to Fabric Interconn
Cisco UCS B200 M4 Blade Server48SUPPLEMENTAL MATERIALThe network adapter options are: Cisco VIC 1340/1240 adapter. This adapter plugs into the mLOM s
Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL49Figure 11 VIC 1340/1240 Port ConnectivityThe number of ports available at the mezzanine adapter
Cisco UCS B200 M4 Blade ServerBASE SERVER STANDARD CAPABILITIES and FEATURES5BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 lists the capabilit
Cisco UCS B200 M4 Blade Server50SUPPLEMENTAL MATERIALMezzanine AdaptersThere are multiple options for the mezzanine slot: I/O-based PCIe adapters (su
Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL51B200 M4 Configured with 1 CPUIn a B200 M4 configured with 1 CPU, the mezzanine card slot is not u
Cisco UCS B200 M4 Blade Server52SUPPLEMENTAL MATERIALIn Figure 13, two ports from the VIC 1340/1240 are channeled to 2208XP Fabric Extender A and two
Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL53Connectivity using the Cisco UCS 2204XP Fabric ExtenderThe Cisco UCS 2204XP is a second-generatio
Cisco UCS B200 M4 Blade Server54SUPPLEMENTAL MATERIALFigure 15 Option 2 - VIC 1340/1240 and Port Expander Card for VIC to UCS 2204XP Fabric Extender
Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL55Connectivity using the Cisco UCS 2104XP Fabric ExtenderThe option shown in Figure 16 demonstrates
Cisco UCS B200 M4 Blade Server56SUPPLEMENTAL MATERIALB200 M4 Configured with 2 CPUsConnectivity using the Cisco UCS 2208XP Fabric ExtenderThe Cisco UC
Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL57In Figure 18, two ports from the VIC 1340/1240 are channeled to 2208XP Fabric Extender A and two
Cisco UCS B200 M4 Blade Server58SUPPLEMENTAL MATERIALIn Figure 20, two ports from the VIC 1340/1240 are channeled to 2208XP Fabric Extender A and two
Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL59Connectivity using the Cisco UCS 2204XP Fabric ExtenderThe Cisco UCS 2204XP is a second-generatio
Cisco UCS B200 M4 Blade Server6BASE SERVER STANDARD CAPABILITIES and FEATURESStorage devices Up to two optional, front-accessible, hot-swappable 2.5
Cisco UCS B200 M4 Blade Server60SUPPLEMENTAL MATERIALIn Figure 23, one port from the VIC 1340/1240 is channeled to 2204XP Fabric Extender A and one is
Cisco UCS B200 M4 Blade ServerSUPPLEMENTAL MATERIAL61In Figure 25, one port from the VIC 1340/1240 is channeled to 2204XP Fabric Extender A and one is
Cisco UCS B200 M4 Blade Server62SUPPLEMENTAL MATERIALConnectivity using the Cisco UCS 2104XP Fabric ExtenderThe options shown in Figure 27 and Figure
Cisco UCS B200 M4 Blade ServerTECHNICAL SPECIFICATIONS63TECHNICAL SPECIFICATIONSDimensions and WeightPower SpecificationsFor configuration-specific po
Cisco UCS B200 M4 Blade Server64TECHNICAL SPECIFICATIONS
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER7CONFIGURING the SERVERFollow these steps to configure the Cisco UCS B200 M4 Blade Server: STEP 1
Cisco UCS B200 M4 Blade Server8CONFIGURING the SERVERSTEP 1 VERIFY SERVER SKUVerify the product ID (PID) of the server as shown in Table 2.The base Ci
Cisco UCS B200 M4 Blade ServerCONFIGURING the SERVER9STEP 2 CHOOSE CPU(S)The standard CPU features are: Intel Xeon E5-2600 v3 series processor family
Comments to this Manuals