DS62-Network, DS62-MD4 Network/Modem Host Module
7
PREPARING THE INSTALLATION SITE
The installation area should be clean and free of extreme temperatures and humidity. Allow sufficient
space behind the DS unit for cabling and receptacle connections. Access to installation site should be
restricted to authorized personnel. Installation of these units should be limited to ITE and Telco server
environments.
Power
CAUTION: This unit is intended for indoor use only. Do not install near water or expose this
unit to moisture. To prevent heat buildup, do not coil the power cord when in use. Do not use
extension cords. Do not attempt to make any internal changes to the power source. Do not
attempt to modify any portion or component of a DS-Series Data Switch unless specifically
directed to; as in Appendix E of this manual. BayTech must perform any internal changes.
CAUTION: High-voltage surges and spikes can damage this equipment. To protect from such
power surges and spikes, this unit must have a good earth ground. A grounding screw
connection is located near the power switch on the back of the unit.
CAUTION: Before removing or replacing any modules, turn off main power switch located on
the DS-Series Base Unit. Communication to the DS-Series Data Switch will be disrupted while
power is off.
CAUTION: For PERMANENTLY CONNECTED EQUIPMENT, a readily accessible
disconnect device (Circuit Breaker rated not to exceed the amperage rating of the unit) shall be
incorporated in the fixed wiring between the power source and the Baytech unit. For
PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and easily
accessible and shall provide back up protection against over current and short circuit by
suitable rated protective devices
not to exceed the AC current rating for the selected model
QUICK START: HOST Module
by Bay Technical Associates
For those Administrators who have requested the bare minimum for this type of equipment, follow
these steps exactly. If this is a new unit shipped directly from Baytech, follow the steps. If this is a
previously own unit, perform a factory reset to clear out any users and passwords still in the unit.
Ethernet Controller Configuration:
Before continuing your System Administrator needs to tell you to use DHCP or give you an IP
Address, Subnet Address, and Gateway Address.
1. Connect the 9FRJ45PC-4 or 9FRJ45PC-1 adapter to your PC.
2. Connect the supplied rollover flat cable RJ08X007 to the adapter and to the EIA232 serial port
on the Baytech HOST Module.
3. Use terminal emulation software to access the unit, (i.e. Microsoft Hyper-terminal). Set the PC
serial port configuration to the following: 9600 bps, 8 data bits, 1stop bit and no parity.
4. If you get only a blinking cursor Press ‘Enter’. If still only a blinking cursor, Type 5 semi-colons
(;), The Attention Character will not echo on the screen. There is a one second delay before
the menu is displayed. You should see a menu similar to (Figure 1).