© 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 8 of 9
Temperature Range IE 2000U Operating Temperature Range Support
IND -40ºF to +158ºF (-40ºC to +70ºC)
EXT +23ºF to +158ºF (-5ºC to +70ºC)
COM +32ºF to +131ºF (0ºC to +55ºC)
Safety and Compliance
Table 9 gives safety and compliance information for the IE 2000U.
Table 9. Safety and Compliance Specifications
Description Specification
Environmental substation compliance
●
IEC 61850-3 (reference certificate of approval)
●
IEEE1613 (reference certificate of approval)
EMC interface immunity
●
IEC61000-4-2 (Criteria A—Class 2)
●
IEC61000-4-3/ENV50204 (Criteria A)
●
IEC61000-4-4 (Criteria A/Criteria B)
●
IEC61000-4-5 (Criteria B)
●
IEC61000-4-6 (Criteria A)
Standard electromagnetic emissions
certifications
●
FCC Part 15 Class A
●
EN 55022B Class A (CISPR22 Class A)
●
EN 55024
●
EN 300 386
●
VCCI Class I
●
AS/NZS 3548 Class A or AS/NZS CISPR22 Class A
●
KCC
●
CE Marking
Standard safety certifications
●
UL 60950-1
●
CSA 60950-1
●
EN 60950-1
●
IEC 60950-1
●
ITE 60950-1
●
UL 508
Operating environment
●
-40 ºF to 158ºF (-40 to +70ºC) continuous operating temperature range
●
-40 ºF to 185ºF (-40 to +85ºC) type tested at 85ºC
●
Operating altitude: -60 m (-200 ft) to 3,000 m (10,000 ft), derate maximum operating
temperature per IEEE-1613-2009
●
Relative humidity: 5% to 95% noncondensing
Storage environment
●
Temperature: -50ºC to +85 ºC
●
Altitude: 15,100 ft (4,600 m)
Warranty Information
IE 2000U Series Switches come with a five-year limited hardware warranty. More information is available on
www.cisco-servicefinder.com/warrantyfinder.aspx.