Removing and Installing the Cisco AS5350 Power Supply
78-4519-04
Removing and Installing the Cisco AS5350 Power Supply
Step 7 Reconnect the AC power cord or rewire the DC power supply.
Warning
After wiring the DC power supply, remove the tape from the circuit breaker switch handle and
reinstate power by moving the handle of the circuit breaker to the ON position. To see translations of
the warnings that appear in this publication, refer to the Regulatory Compliance and Safety
Information document that accompanied this device.
Step 8 Power on the access server.
The internal power supply fan should power on.
Removing and Installing the Cisco AS5350 Power Supply
The Cisco AS5350 universal gateway supports a single power supply or a redundant power supply. A
redundant power supply has two power connections and provides higher reliability and load balancing.
You can use the redundant power supply to:
Manage your system with alarms and other management features.
Provide higher reliability with a second built-in power supply connected to a second power source.
Balance loads.
Note The redundant power supply on the Cisco AS5350 requires Cisco IOS Release 12.2(2)XB5 or later
release.
The following sections describe how to remove and install the Cisco AS5350 power supply:
Removing the Chassis Cover, page 21
Removing the Old Power Supply, page 25
Installing the Power Supply, page 29
Replacing the Chassis Cover, page 31
Removing the Chassis Cover
You must open the universal gateway chassis to gain access to its interior components.
To open the chassis, follow these steps:
Step 1 Turn the power switch on the universal gateway off and disconnect site power.
Note Note that the power switch is part of the power supply.
Note If you are using a DC-powered unit, refer to Figure 21 or Figure 22 and complete Step a through
Step d.