Release Notes for Cisco Aironet Access Points and Bridges for Cisco IOS Release 15.2(2)JA
OL-23990-01
Installation Notes
Roaming improvements (for client workgroup bridges):
This release improves the reliability of fast roaming on workgroup bridges by allowing the unit
an additional retry when it needs to reassociate to the root access point.
This release also improves the method that workgroup bridges use to select the “best parent”
access point. Workgroup bridges can share association histories with rot access points, which
can build and share a list of best root access points among workgroup bridges. This method
improves helps workgroup bridges select the best root access point when roaming.
VideoStream support on workgroup bridges (when used as a client): VideoStream improves the
reliability of an IP multicast stream by converting the multicast frame, over the air, to a unicast
frame. VideoStream was not supported for workgroup bridge clients in previous releases because a
workgroup bridge’s wired clients cannot be added to the controller (WLC) multicast table. In this
release, the workgroup bridge is added to the WLC multicast table, and the workgroup bridge
converts the VideoStream unicast frame into an Ethernet multicast frame and sends it out to its wired
clients.
Enter this command on the controller to enable VideoStream for workgroup bridges:
config media-stream wired-client enable
Installation Notes
This section contains information that you should keep in mind when installing 1040, 1130, 1140, 1240,
1250, 1260, and 2600 series access points, and 1300 and 1400 access points/bridges.
Access Points
This section contains installation notes for access points.
Installation in Environmental Air Space
Cisco Aironet 1040, 1130, 1140, 1240, 1250, 1260, and 2600 Series Access Points provide adequate fire
resistance and low smoke-producing characteristics suitable for operation in a building's environmental
air space, such as above suspended ceilings, in accordance with Section 300-22(C) of the National
Electrical Code (NEC) and Sections 2-128, 12-010(3) and 12-100 of the Canadian Electrical Code, Part
1, C22.1.
Caution The power injector does not provide fire resistance and low smoke-producing characteristics and is not
intended for use in extremely high or low temperatures or in environmental air spaces such as above