Page 7 of 14
Specification Standard
Input Level
_ down to -24 dB0
Line Frequency
1.544 Mbps 75 bps/32PPM
2.048 Mbps 75 bps/32PPM
DTE/DCE Interface (VIC Mode)
G.704/structured
Diagnostic Loopback Support
ANSI T1.403 Annex B/V.54 loopup/down code recognition, network loopback, and user initiated
loopbacks, network payload loopback, local DTE loopback, remote line (codes: V.541, loop up, and
loop down)
Alarm Detection
Alarm indication signal (AIS), remote alarm, far-end block error (FEBE), out of frame (OOF), cyclic
redundancy check (CRC) multiframe OOF, signaling multiframe OOF, frame errors, CRC errors, Loss
of network signal (red alarm), loss of network frame, receive (blue alarm) (AIS) from network, receive
(yellow) from network Performance Reports/Error Counters CRC, errored seconds, burst errored
seconds, severely errored seconds, Ft and Fs framing errors for SF framing, FPS framing errors for ESF
framing, 24-hour history stored in 15-minute increments
LED Indicators
Data carrier detect (CD)
Loopback (LP)
Alarm (AL)
Voice DSP processing status
DSU/CSU
Selectable DSX-1 cable length in increments from 0 to 655 feet in DSU mode
Selectable DS1 CSU line build-out: 0, -7.5, -15, and -22.5 dB
Selectable DS1 CSU receiver gain: 26 or 36 dB
Physical Interface Standards
T1 ANSI, ATT T1.1, ANSI T1.403
Environmental
Operating temperature: 0 to 40º C (32 to 104° F)
Storage temperature: -25 to º C (-13 to 158° F)
Relative humidity: 5 to 85% noncondensing operating; 5 to 95% noncondensing, nonoperating
MTBF
NM-HDV-1T1-24E; 381,087 to 467,253 hours
NM-HDV-2T1-48; 366,394 to 445,354 hours
Page view 6