Cisco N2XX-AEPCI05= Datasheet

Browse online or download Datasheet for Networking cards Cisco N2XX-AEPCI05=. Cisco Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Rack-Mount Server

CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.7 JANUARY 5, 2015 WWW.CISCO.COMSpec SheetCisco UCS C24 M3High-Density

Page 2

Cisco UCS C24 M3 High-Density LFF Rack Server10CONFIGURING the SERVERSTEP 2 SELECT CPU(s)The standard CPU features are: Intel Xeon E5-2400 v2 or E5-2

Page 3 - OVERVIEW

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER11Approved Configurations(1) 1-CPU configurations: Select any one CPU listed in Ta

Page 4 - DETAILED VIEWS

Cisco UCS C24 M3 High-Density LFF Rack Server12CONFIGURING the SERVERSTEP 3 SELECT MEMORYThe standard memory features are: DIMMs— Clock speed: 1600 o

Page 5 - Chassis Rear View

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER13Select DIMMsSelect the memory configuration. The available memory DIMMs are liste

Page 6

Cisco UCS C24 M3 High-Density LFF Rack Server14CONFIGURING the SERVER(2) 1-CPU configuration with memory mirroring: Select 2 or 4 DIMMs. The DIMMs wi

Page 7

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER15 By default, all DIMMs run at 1.35 V, which yields 1333-MHz memory speeds. To ru

Page 8

Cisco UCS C24 M3 High-Density LFF Rack Server16CONFIGURING the SERVERSTEP 4 SELECT RAID CONFIGURATION(1) One PCIe RAID controller Cisco can provide fa

Page 9 - STEP 1 VERIFY SERVER SKU

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER17UCS-RAID9270CV-8i LSI MegaRAID 9270CV-8i (with supercap power backup) Supports u

Page 10 - STEP 2 SELECT CPU(s)

Cisco UCS C24 M3 High-Density LFF Rack Server18CONFIGURING the SERVERApproved Configurations(1) 1-CPU ConfigurationsSelect a PCIe RAID controller from

Page 11

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER19the controller selected. RAID levels 50 and 60 are supported, depending on the RA

Page 12 - STEP 3 SELECT MEMORY

Cisco UCS C24 M3 High-Density LFF Rack-Mount Server2 OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 13 - CONFIGURING the SERVER

Cisco UCS C24 M3 High-Density LFF Rack Server20CONFIGURING the SERVERSTEP 5 SELECT HARD DISK DRIVES (HDDs)The standard disk drive features are: 3.5-i

Page 14

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER21Approved Configurations(1) LSI MegaRAID 9270CV-8i (with data cache and supercap),

Page 15

Cisco UCS C24 M3 High-Density LFF Rack Server22CONFIGURING the SERVERSTEP 6 SELECT PCIe OPTION CARD(s)The standard PCIe card offerings are: Converged

Page 16

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER23 If you did not choose a PCIe RAID controller, from Table 7 you can select up to

Page 17

Cisco UCS C24 M3 High-Density LFF Rack Server24CONFIGURING the SERVERChoose Optional Twinax CablesTab le 8 lists the copper twinax cables available f

Page 18

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER25redundant network switching equipment. With the SFP+ optical modules, you can use

Page 19

Cisco UCS C24 M3 High-Density LFF Rack Server26CONFIGURING the SERVERTable 10 PCIe Card Compatibility PCIe CardsTwinax CablesCisco SFP ModulesSFP-1

Page 20

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER27Figure 5 Network Card ConnectionsN2XX-AQPCI05 (QLogic QLE2562 Dual Port 8Gb Fib

Page 21

Cisco UCS C24 M3 High-Density LFF Rack Server28CONFIGURING the SERVERSTEP 8 SELECT AC POWER CORD(s)Using Table 11, select the appropriate AC power cor

Page 22

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER29CAB-9K10A-AU Power Cord, 250VAC 10A 3112 Plug, AustraliaSFS-250V-10A-CN Power Cor

Page 23

Cisco UCS C24 M3 High-Density LFF Rack ServerOVERVIEW3 OVERVIEWThe Cisco® UCS C24 M3 Rack Server combines economics and a density-optimized feature se

Page 24

Cisco UCS C24 M3 High-Density LFF Rack Server30CONFIGURING the SERVERCAB-9K10A-SW Power Cord, 250VAC 10A MP232 Plug, SwitzerlandCAB-9K10A-UK Power Cor

Page 25

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER31STEP 9 ORDER POWER SUPPLIESThe C24 M3 server accommodates two power supplies. A l

Page 26

Cisco UCS C24 M3 High-Density LFF Rack Server32CONFIGURING the SERVERSTEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARMThe reversible cable manage

Page 27

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER33STEP 11 ORDER A TRUSTED PLATFORM MODULETrusted Platform Module (TPM) is a compute

Page 28

Cisco UCS C24 M3 High-Density LFF Rack Server34CONFIGURING the SERVERSTEP 12 ORDER OPTIONAL USB 2.0 DRIVESYou may order one optional USB 2.0 drive. On

Page 29

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER35STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARESeveral operating systems

Page 30

Cisco UCS C24 M3 High-Density LFF Rack Server36CONFIGURING the SERVERRed Hat Enterprise LinuxRHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs RequiredRHEL

Page 31 - STEP 9 ORDER POWER SUPPLIES

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER37VMware 5VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support

Page 32

Cisco UCS C24 M3 High-Density LFF Rack Server38CONFIGURING the SERVERSTEP 14 SELECT OPERATING SYSTEM MEDIA KITSelect the optional operating system med

Page 33

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER39STEP 15 SELECT SERVICE and SUPPORT LEVELA variety of service options are availabl

Page 34

Cisco UCS C24 M3 High-Density LFF Rack Server4DETAILED VIEWSDETAILED VIEWSChassis Front ViewFigure 2 shows the Cisco UCS C24 M3 High-Density LFF Rack

Page 35

Cisco UCS C24 M3 High-Density LFF Rack Server40CONFIGURING the SERVERSMARTnet for UCS Hardware Only ServiceFor faster parts replacement than is provid

Page 36

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER41See Table 20.Partner Support Service for UCS Hardware Only provides customers wit

Page 37

Cisco UCS C24 M3 High-Density LFF Rack Server42CONFIGURING the SERVERYou can choose a service listed in Table 22.Unified Computing Drive Retention Ser

Page 38

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER43For more service and support information, see the following URL:http://www.cisco.

Page 39

Cisco UCS C24 M3 High-Density LFF Rack Server44OPTIONAL STEP - ORDER RACK(s)OPTIONAL STEP - ORDER RACK(s)The optional R42610 rack is available from Ci

Page 40

Cisco UCS C24 M3 High-Density LFF Rack ServerOPTIONAL STEP - ORDER PDU45OPTIONAL STEP - ORDER PDUAn optional power distribution unit (PDU) is availabl

Page 41

Cisco UCS C24 M3 High-Density LFF Rack Server46SUPPLEMENTAL MATERIALSUPPLEMENTAL MATERIALCHASSISAn internal view of the C24 M3 chassis with the top co

Page 42

Cisco UCS C24 M3 High-Density LFF Rack ServerSUPPLEMENTAL MATERIAL47CPUs and DIMMsPhysical LayoutEach CPU has three DIMM channels: CPU1 has channels

Page 43

Cisco UCS C24 M3 High-Density LFF Rack Server48SUPPLEMENTAL MATERIALMemory Population RulesWhen considering the memory configuration of your server, y

Page 44 - OPTIONAL STEP - ORDER RACK(s)

Cisco UCS C24 M3 High-Density LFF Rack ServerSUPPLEMENTAL MATERIAL49Recommended Memory PopulationThis section explains the recommended DIMM population

Page 45 - OPTIONAL STEP - ORDER PDU

Cisco UCS C24 M3 High-Density LFF Rack ServerDETAILED VIEWS5Chassis Rear ViewFigure 3 shows the external features of the rear panel.Figure 3 Chassis

Page 46 - SUPPLEMENTAL MATERIAL

Cisco UCS C24 M3 High-Density LFF Rack Server50SUPPLEMENTAL MATERIALAdditional DIMM PopulationsThe list in Table 27 is not a complete list of all supp

Page 47 - CPUs and DIMMs

Cisco UCS C24 M3 High-Density LFF Rack ServerSUPPLEMENTAL MATERIAL51Low-Voltage DIMM ConsiderationsThe C24 M3 server can be ordered with low-voltage (

Page 48 - Memory Population Rules

Cisco UCS C24 M3 High-Density LFF Rack Server52SUPPLEMENTAL MATERIALRAID SummaryThe C24 M3 LFF server can be ordered with a 12-drive backplane with a

Page 49 - Recommended Memory Population

Cisco UCS C24 M3 High-Density LFF Rack ServerSUPPLEMENTAL MATERIAL53RAID Option ROM (OPROM) SettingsThe server contains an Option ROM (OPROM) for the

Page 50 - Additional DIMM Populations

Cisco UCS C24 M3 High-Density LFF Rack Server54SUPPLEMENTAL MATERIALRACKSThe Cisco R42610 rack (see Figure 9) is certified for Cisco UCS installation

Page 51

Cisco UCS C24 M3 High-Density LFF Rack ServerSUPPLEMENTAL MATERIAL55Figure 9 Cisco R42610 RackFront view - door closed Front view - door open Front

Page 52 - RAID Summary

Cisco UCS C24 M3 High-Density LFF Rack Server56SUPPLEMENTAL MATERIALPDUsCisco RP Series Power Distribution Units (PDUs) offer power distribution with

Page 53

Cisco UCS C24 M3 High-Density LFF Rack ServerSUPPLEMENTAL MATERIAL57Motherboard USB PortThe C24 M3 LFF motherboard has one general-purpose USB socket

Page 54

Cisco UCS C24 M3 High-Density LFF Rack Server58SUPPLEMENTAL MATERIALLED IndicatorsThe server contains LED indicators on the front and rear panels. The

Page 55 - Figure 9 Cisco R42610 Rack

Cisco UCS C24 M3 High-Density LFF Rack ServerSUPPLEMENTAL MATERIAL59Blinking (amber) The hard drive is rebuildingHard Drive Activity Off There is no h

Page 56

Cisco UCS C24 M3 High-Density LFF Rack Server6BASE SERVER STANDARD CAPABILITIES and FEATURESBASE SERVER STANDARD CAPABILITIES and FEATURESTab le 1 li

Page 57 - Motherboard USB Port

Cisco UCS C24 M3 High-Density LFF Rack Server60SUPPLEMENTAL MATERIALRear PanelFigure 13 shows the rear panel LEDs.Figure 13 Rear Panel LEDsSystem St

Page 58 - LED Indicators

Cisco UCS C24 M3 High-Density LFF Rack ServerSUPPLEMENTAL MATERIAL61See Table 31 for the functions of the rear panel LEDs.1 Power supply fault LED 5 1

Page 59

Cisco UCS C24 M3 High-Density LFF Rack Server62SUPPLEMENTAL MATERIALUnit ID (LED is integrated into unit ID button)Off Unit ID not activeOn (blue) Uni

Page 60 - Rear Panel

Cisco UCS C24 M3 High-Density LFF Rack ServerTECHNICAL SPECIFICATIONS63TECHNICAL SPECIFICATIONSDimensions and WeightPower SpecificationsThe general po

Page 61

Cisco UCS C24 M3 High-Density LFF Rack Server64TECHNICAL SPECIFICATIONSThe general power specifications for the C24 M3 LFF server 650 W power supply a

Page 62

Cisco UCS C24 M3 High-Density LFF Rack ServerTECHNICAL SPECIFICATIONS65Environmental SpecificationsThe power specifications for the C24 M3 server are

Page 63 - TECHNICAL SPECIFICATIONS

Cisco UCS C24 M3 High-Density LFF Rack Server66TECHNICAL SPECIFICATIONSCompliance RequirementsThe regulatory compliance requirements for C-Series serv

Page 64

Cisco UCS C24 M3 High-Density LFF Rack ServerBASE SERVER STANDARD CAPABILITIES and FEATURES7Video The Emulex Pilot 3 Integrated Baseboard Management C

Page 65 - Environmental Specifications

Cisco UCS C24 M3 High-Density LFF Rack Server8CONFIGURING the SERVERCONFIGURING the SERVERFollow these steps to configure the Cisco UCS C24 M3 High-De

Page 66 - Compliance Requirements

Cisco UCS C24 M3 High-Density LFF Rack ServerCONFIGURING the SERVER9STEP 1 VERIFY SERVER SKUThe 12-drive version of the server has a SAS expander enab

Comments to this Manuals

No comments