Page view 156
TraverseEdge 2020 Applications and Engineering Guide, Chapter 8: Node Synchronization
Release 5.0.x Turin Networks Page 8-3
Figure 8-2 BITS Terminations
Figure 8-3 Synchronization Wire-wrap Post Identification
Line Timing
The TE-2020 system supports line timing where a received clock signal is taken from any incoming
SONET OC-n interface to serve as a synchronization source. This does not include non-optical EC-1 sig-
nals that are available in the DS3/EC1 Tributary Shelf. A single optical interface per tributary shelf can be
used in the timing reference list.
Loop Timing
Loop timing is a special case of line timing that applies to TE-2020 systems that are configured for only
one OC-n interface. In providing the capability to line time its fiber interfaces, the TE-2020 inherently pro-
vides the capability to loop time any of its fiber interfaces. Loop timing entails using the received timing as
a reference to clock the transmitter, effectively looping the timing reference back out to the transmit side
of the network.