5
Installing ONS 15454 SDH MIC-C/T/P Cards
78-14311-01
Installation Procedures
MIC-C/T/P cards have electrical plugs that plug into electrical connectors on the shelf assembly
backplane. When the ejectors are fully closed and the mounting screws are tightened, the card plugs into
the shelf assembly backplane. Figure 3 on page 5 shows general card installation. Connecting the power
cable is described in Chapter 1 “Installation” of the Cisco ONS 15454 SDH Installation and Operations
Guide.
Figure 3 Installing an FMEC card in an ONS 15454 SDH
Card Turn Up
Follow the steps in this section to verify card turn up. If one or more of the Cisco Transport Controller
(CTC) software screen conditions according to “Verify Successful Turn Up of the MIC-C/T/P Card”
section on page 5 are not met, re-install the card. Replace the unit if the faulty state persists.
Verify Successful Turn Up of the MIC-C/T/P Card
Step 1 Verify that power is applied to the shelf assembly.
Step 2 Verify that the MIC-C/T/P card has been installed in slot 24.
Step 3 Verify that the card appears in slot 24 on the CTC software screen.
Step 4 Verify that the card is white on the CTC software screen.
61338
FAN FAIL
CRIT
MAJ
MIN
M
ounting screws
Guide rail