Sample of Single Door POE Connection
Weigand
Reader
Reader & Lock
Power: Total Draw
650 mA at 12 V
REX
Door Sensor
Strike/Lock
Ouput (NO)
Weigand readers can be
configured with a single 10 wire
interface (including Power and
GND) or as two 5 Wire readers.
The Power and GND connections
are shared between the two
readers in this instance.
Peak Current
Device Description Consumption (mA)
HID 6005
HID Prox
Point Reader
75
HES RF5010
HES
Integrated
Reader &
Strike
240
Example POE Devices