Cisco UCS B200 M4 Blade Server
CONFIGURING the SERVER
23
Supported Configurations
The supported configurations are listed in Table 9. Choose one configuration. Refer to B200 M4
Configured with 1 CPU on page 52 and B200 M4 Configured with 2 CPUs on page 57 for more
details.
Table 9 Supported B200 M4 I/O Configurations
Adapter Configurations
Fabric Extenders Aggregate
Bandwidth
Fabric Interconnects CPU Dependency
Adapter
Slot 1
Adapter Slot 2 2 x
2208XP
2 x
2204XP
2 x
2104XP
1
1. Supported only through UCS Manager version 2.2(3a) and later.
2 x 61xx
1
2 x 62xx
VIC 1340 not populated 40 Gb/s 20 Gb/s not
supported
not
supported
62xx 1 or 2 CPUs
VIC 1340 Port Expander
Card for VIC
80 Gb/s 40 Gb/s not
supported
not
supported
62xx 1 or 2 CPUs
VIC 1340 VIC 1380 80 Gb/s 40 Gb/s not
supported
not
supported
62xx Requires 2 CPUs
VIC 1340 non-IO mezz (for
example,
Fusion-io)
40 Gb/s 20 Gb/s not
supported
not
supported
62xx Requires 2 CPUs
VIC 1240 not populated 40 Gb/s 20 Gb/s 20 Gb/s
61xx
1
62xx 1 or 2 CPUs
VIC 1240 Port Expander
Card for VIC
80 Gb/s 40 Gb/s IO card in
slot 2
ignored
61xx
1
62xx 1 or 2 CPUs
VIC 1240 VIC 1280 80 Gb/s 40 Gb/s IO card in
slot 2
ignored
61xx
1
62xx Requires 2 CPUs
VIC 1240 non-IO mezz (for
example,
Fusion-io)
40 Gb/s 20 Gb/s 20 Gb/s
61xx
1
62xx Requires 2 CPUs
Comments to this Manuals