Mode = Duplex
!−−− Indicates secondary is present and in redundant state.
Unit = Primary
!−−− Always is primary because this is RPR mode.
Unit ID = 2
!−−− Slot number of active.
Redundancy Mode (Operational) = RPR
!−−− Indicates redundancy mode.
Redundancy Mode (Configured) = RPR
Split Mode = Disabled
Manual Swact = Enabled
Communications = Up
client count = 4
client_notification_TMR = 60000 milliseconds
keep_alive TMR = 9000 milliseconds
keep_alive count = 0
keep_alive threshold = 18
RF debug mask = 0x0
If the standby module is not operational because it is in ROMmon or other reasons, or it is not
present, this output displays:
Switch#show redundancy states
my state = 13 −ACTIVE
peer state = 1 −DISABLED
!−−− Standby supervisor is not up or not present.
Mode = Simplex
!−−− Not redundant.
Unit = Primary
Unit ID = 2
Redundancy Mode (Operational) = RPR
Redundancy Mode (Configured) = RPR
Split Mode = Disabled
Manual Swact = Disabled Reason: Simplex mode
Communications = Down Reason: Simplex mode
client count = 4
client_notification_TMR = 60000 milliseconds
keep_alive TMR = 9000 milliseconds
keep_alive count = 0
keep_alive threshold = 18
RF debug mask = 0x0
Manual Switchover Commands
These commands can be used to perform manual switchover or power−cycle of the supervisor:
reloadThis reloads the current active supervisor in order to perform a switchover to the standby.•