Release Notes for Cisco IOS Release 12.1E on the Catalyst 6500 and Cisco 7600 Supervisor Engine and MSFC
OL-2310-11
Caveats
Cisco Catalyst 6000, 6500 series and Cisco 7600 series that have a Network Analysis Module
installed are vulnerable to an attack, which could allow an attacker to gain complete control of the
system. Only Cisco Catalyst systems that have a NAM on them are affected. This vulnerability
affects systems that run Cisco IOS or Catalyst Operating System (CatOS).
Cisco has made free software available to address this vulnerability for affected customers.
A Cisco Security Advisory for this vulnerability is posted at
http://www.cisco.com/warp/public/707/cisco-sa-20070228-nam.shtml
This problem is resolved in Release 12.1(27b)E1.(CSCse52951)
Resolved Service Module Caveats in Release 12.1(27b)E
None.
OSM Caveats
Open OSM Caveats in Release 12.1(27b)E2, page 131
Resolved OSM Caveats in Release 12.1(27b)E2, page 131
Resolved OSM Caveats in Release 12.1(27b)E1, page 131
Resolved OSM Caveats in Release 12.1(27b)E, page 131
Open OSM Caveats in Release 12.1(27b)E2
None.
Resolved OSM Caveats in Release 12.1(27b)E2
None.
Resolved OSM Caveats in Release 12.1(27b)E1
None.
Resolved OSM Caveats in Release 12.1(27b)E
After frequent optical service module (OSM) online OIRs, you might see the following error
message and a reload of the OSM.
%FABRIC-SP-6-TIMEOUT_ERR: Fabric in slot 8 reported timeout error for channel 10
(Module 4, fabric connection 0)
This problem is resolved in Release 12.1(27b)E. (CSCef12193)
On a Supervisor Engine 2, RSPAN does not work when configured on OSM Gigabit Ethernet LAN
ports. This problem is resolved in Release 12.1(27b)E. (CSCsc24089)
A system might learn MAC addresses from the wrong port. This problem occurs when the system
is connected to an 802.1Q trunk with one of the subinterfaces configured for bridging. This problem
only occurs for OSM-4GE-WAN-GBIC and OSM-2+4GE-WAN+ GE-WAN ports. This problem is
resolved in Release 12.1(27b)E. (CSCed11719)
A rounded shape and bandwidth parameter is not displayed when you enter the show policy-map
interface interface-name command for an OSM module. This problem is resolved in
Release 12.1(27b)E. (CSCsa80609)