Release Notes for Cisco IOS Release 12.1E on the Catalyst 6500 and Cisco 7600 Supervisor Engine and MSFC
OL-2310-11
Caveats
Resolved FlexWAN Caveats in Release 12.1(26)E
When you modify the configuration of a serial interface, you might see messages similar to these:
%INTERFACE_API-3-NODESTROYSUBBLOCK: The HWIDB subblock named COPS_PR was not removed
-Traceback=
This problem is resolved in Release 12.1(26)E. (CSCin65698)
The output packet counter for multilink and distributed link fragmentation and interleaving (dLFI)
interfaces displays double the actual traffic count. This problem is resolved in Release 12.1(26)E.
(CSCin40374)
Variable bit rate (VBR) permanent virtual circuits (PVCs) on ATM OC3 port adapters might not pass
any traffic. This problem is resolved in Release 12.1(26)E. (CSCeg29906)
With a Supervisor Engine 2 and a PA-MC-8TE1+ port adapter, the E1 interfaces might stay down
after switchover to a redundant supervisor engine. This problem is resolved in Release 12.1(26)E.
(CSCeg11283)
The SNMP ifAdminStatus MIB object does not support ATM subinterfaces. This problem is
resolved in Release 12.1(26)E. (CSCeg03153)
With more than 38 multilink bundles configured on a port adapter, a reload might occur if CEF
switching is disabled. This problem is resolved in Release 12.1(26)E. (CSCef94525)
With an E3 serial port adapter, when you enter the dsu bandwidth kbps_rate command, the DSU
bandwidth might not change. This problem is resolved in Release 12.1(26)E. (CSCef73120)
On a PA-MC-2T3+ port adapter, serial subrate interfaces do not follow the up or down state of the
port adapter controller. This problem is resolved in Release 12.1(26)E. (CSCef61641)
With a PA-MC-STM1 port adapter, in some topologies the clock source line command does not
work and is not saved in the configuration. This problem is resolved in Release 12.1(26)E.
(CSCef56327)
With non-real time variable bit rate (VBR-nrt) shaping configured on more than one permanent
virtual circuit (PVC) defined under the same physical ATM interface on a PA-A3-8E1IMA or
PA-A3-8T1IMA port adapter, when the load is equal to or greater than the maximum configured
VBR-nrt value on at least two PVCs, not all of the PVCs achieve the configured VBR-nrt value. This
problem is resolved in Release 12.1(26)E. (CSCef55463)
When a PA-MC-2T3+ goes down for a short time and an alarm occurs, the port adapter does not
report the type of alarm. This problem is resolved in Release 12.1(26)E. (CSCee49983)
Following a reload, the vbr-nrt command might be missing from inverse multiplexing over ATM
(IMA) interfaces. This problem is resolved in Release 12.1(26)E. (CSCec51408)
High traffic flow rates (for example, 60 percent or more of capacity) through a PA-A3 ATM port
adapter might cause a reload. This problem is resolved in Release 12.1(26)E. (CSCdy46272)
The PA-MC-2T3+ port adapter does not delay for two seconds before bringing down the T3
controller in the event of an alarm as required by the ANSI T1.231 specification. This problem is
resolved in Release 12.1(26)E. (CSCee49862)
The PA-2T3+ port adapter does not delay for two seconds before bringing down the T3 controller
in the event of an alarm as required by the ANSI T1.231 specification. This problem is resolved in
Release 12.1(26)E. (CSCee70591)
1,500-byte pings fail on a PA-A3 ATM subinterface configured for MPLS and configured with the
ip mtu 1500 command. This problem is resolved in Release 12.1(26)E. (CSCef91994)