Release Notes for Cisco IOS Release 12.1E on the Catalyst 6500 and Cisco 7600 Supervisor Engine and MSFC
OL-2310-11
Caveats
Receipt of a large packet that was fragmented by another network device might cause this message
to be displayed at the rendezvous point of a multicast network that is running Protocol Independent
Multicast (PIM) sparse mode:
%PIM-5-REG_ENCAP_INVALID:Bad register from IP_address for (IP_address,
Class_D_IP_address). Trace = ....
This problem is resolved in Release 12.1(4)E1. (CSCdr49641)
Configuring the source VLAN and filter VLAN of the monitor (SPAN) feature can result in a heap
corruption fault and crash. This problem is resolved in Release 12.1(4)E1. (CSCds56632)
To avoid a fatal exception, do not configure a VLAN as both a monitor session source VLAN and a
filter VLAN. This problem is resolved in Release 12.1(4)E1. (CSCds63640)
With OSPF configured, to avoid multiple MSFCs in the same subnet claiming to be the designated
router, use the loopback interface IP address for each router instead of the interface IP address. This
problem is resolved in Release 12.1(4)E1. (CSCdr08174, CSCds00527)
Release 12.1(3a)E Rebuilds
Open Caveats in Release 12.1(3a)E7, page 315
Resolved Caveats in Release 12.1(3a)E7, page 316
Resolved Caveats in Release 12.1(3a)E4, page 316
Resolved Caveats in Release 12.1(3a)E3, page 316
Open Caveats in Release 12.1(3a)E7
Support for Mobile IP was inadvertently deleted. This problem is resolved in Release 12.1(5a)E1.
(CSCds78103)
You cannot configure the MTU size on VLAN interfaces. For Supervisor Engine 2, this problem is
resolved in Release 12.1(8a)E. For Supervisor Engine 1, this problem is resolved in
Release 12.1(7)E. (CSCdr62024)
The copy running-config startup-config command does not save the boot system flash command
in the startup configuration file. Use the write memory command instead. This problem is resolved
in Release 12.1(6)E. (CSCds43994)
You cannot set the MTU size on VLAN interfaces. For Supervisor Engine 2, this problem is resolved
in Release 12.1(8a)E. For Supervisor Engine 1, this problem is resolved in Release 12.1(7)E.
(CSCdr54103)
For 48 Port 10/100TX RJ-45 Ethernet switching modules (WS-X6248-RJ-45), the output from the
show queueing interface command does not contain the Packets dropped on Transmit section or
the Packets dropped on Receive section. This problem is resolved in Release 12.1(4)E1.
(CSCds39365)
There is no warning message displayed if you exceed the maximum number (63) of microflow
policers. The extra policers are displayed by the show mls qos ip command, but they do not work.
If classes are increased beyond the maximum number (255) in a policy-map, the policy is rejected
without a warning message if applied to an interface. For Supervisor Engine 2, this problem is
resolved in Release 12.1(8a)E. For Supervisor Engine 1, this problem is resolved in
Release 12.1(6)E. (CSCds38349)