Equal wattage power
supply is inserted with
redundancy enabled.
System log and syslog
messages are generated.
•
System power equals the
power capability of one
power supply that already
works.
•
No change in the module
status because the power
capability is unchanged.
•
Equal wattage power
supply is inserted with
combined mode enabled
(redundancy disabled).
System log and syslog
messages are generated.
•
System power is not the
sum of two power supplies.
It is P+ (P * ratio). Refer to
the Available Power for
Catalyst 4500 Series
Switches Power Supplies
section of the product
documentation for more
information.
•
The modules marked as
power−deny in the show
module command output
status field are brought up if
there is sufficient power.
•
Higher or lower wattage
power supply is inserted.
System log and syslog
messages are generated.
•
System power remains the
same.
•
The newly inserted power
supply is kept in
err−disabled mode.
•
No change in the module
status because the power
capability is unchanged.
•
Different type (AC/DC)
power supply is inserted.
System log and syslog
messages are generated.
•
System power remains the
same.
•
The newly inserted power
supply is kept in
err−disabled mode.
•
No change in the module
status because the power
capability is unchanged.
•
Power supply is removed
with redundancy enabled System log and syslog
messages are generated.
•