Chapter 4 Connecting the Cisco RPS
Connecting Hubs
4-6
Cisco Redundant Power System Hardware Installation Guide
OL-3654-01
Step 5 Connect the other end of the Cisco RPS AC power cable into an AC power outlet.
Step 6 If you are using the redundant-with-reboot configuration (not recommended),
power up the switch by connecting the hub AC power cord to an AC power outlet.
Note If you use the redundant-with-reboot configuration, always power up the
hub before you power up the Cisco RPS.
Step 7 Power up the Cisco RPS. There is one power switch for each AC input power
module. Make sure that the power switch is in the ON (|) position for each AC
power module used. (See Figure 4-5.)
Figure 4-5 Powering Up the Cisco RPS
The Cisco RPS provides power in 10 to 15 seconds. The Cisco RPS is working
properly when all its front-panel LEDs are solid green. If the external device does not
power up, refer to Chapter 5, “Troubleshooting the Cisco RPS.”