Data Sheet
© 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 5 of 8
Table 3. Cisco IE 3000 Series Switch Hardware
Description Specification
Performance
●
Wire-speed switching
●
128 MB DRAM
●
64 MB Compact Flash memory
●
Configurable up to 8000 MAC addresses
●
Configurable up to 255 IGMP groups
●
Configurable maximum transmission unit (MTU) of up to 9000 bytes, with a maximum Ethernet
frame size of 9018 bytes (jumbo frames) for bridging on Gigabit Ethernet ports, and up to 1998
bytes for bridging of Multiprotocol Label Switching (MPLS) tagged frames on both 10/100 and
10/100/1000 ports
Connectors and
cabling
●
10BASE-T ports: RJ-45 connectors, two-pair Category 3, 4, or 5 unshielded twisted-pair (UTP)
cabling
●
100BASE-TX ports: RJ-45 connectors, two-pair Category 5 UTP cabling
●
1000BASE-T ports: RJ-45 connectors, four-pair Category 5 UTP cabling
●
1000BASE-SX, -LX/LH, -ZX SFP-based ports: LC fiber connectors (single/multimode fiber)
●
100BASE-LX10, -FX: LC fiber connectors (single/multimode fiber)
Indicators
●
Per-port status LED: Link integrity, disabled, activity, speed, full-duplex indications
●
System-status LED: System, link status, link duplex, link speed, indications
Dimensions
(H x W x D)
●
Cisco IE-3000-4TC: 6.0”W x 5.8”H x 4.4”D (152mm H x 147mm W x 112mm D)
●
Cisco IE-3000-8TC: 6.0”W x 5.8”H x 4.4”D (152mm H x 147mm W x 112mm D)
●
Cisco IEM-3000-8TM=: 3.5”W x 5.8”H x 4.4”D (89mm H x 147mm W x 112mm D)
●
Cisco IEM-3000-8FM=: 3.5”W x 5.8”H x 4.4”D (89mm H x 147mm W x 112mm D)
●
Cisco PWR-IE3000-AC=: 2.0”W x 5.8”H x 4.4”D (51 mm H x 147mm W x 112mm D)
Weight
●
Cisco IE-3000-4TC: 4.4 lb (2.0 kg)
●
Cisco IE-3000-8TC: 4.4 lb (2.0 kg)
●
Cisco IEM-3000-8TM=: 2.2 lb (1.0 kg)
●
Cisco IEM-3000-8FM=: 3.2 lb (1.45 kg)
●
Cisco PWR-IE3000-AC=:: 1.4 lb (0.65 kg)
Environmental ranges
●
Operating temperature: -40 to 167ºF (–40 to 75ºC)
●
Storage temperature: -13 to 185ºF (–25 to 85ºC)
●
Operating relative humidity: 10 to 95% (condensing)
●
Operating altitude: Up to 10,000 ft (3049m)
●
Storage altitude: Up to 15,000 ft (4573m)
Mean time between
failure (MTBF)
●
Cisco IE-3000-4TC: 363,942
●
Cisco IE-3000-8TC: 329,451
●
Cisco IEM-3000-8TM=: 926,999
●
Cisco IEM-3000-8FM=: 264,689
●
Cisco PWR-IE3000-AC=: 1,662,359
Table 4. Power Specifications for Cisco IE300 Series Switch
Description Specification
Maximum power consumption
●
15.1W (IE-3000-4TC)
●
15.7W (IE-3000-8TC)
●
2.8W (IEM-3000-8TM=)
●
10.1W (IEM-3000-8FM=)
Input voltage and currents
supported
●
18-60VDC, (Cisco IE-3000-4TC and Cisco IE-3000-8TC)
●
85-265VAC/88-300VDC, 1.3-0.8A, 50-60 Hz (with addition of Cisco PWR-IE3000-
AC=)
Power rating
●
Cisco IE-3000-4TC: .05KVA
●
Cisco IE-3000-8TC: .05KVA
Comments to this Manuals