Data Sheet
© 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 6 of 8
Table 5. Management and Standards Support for Cisco IE 3000 Series Switch
Description Specification
Standards
●
100BASE-X (SFP)
●
1000BASE-X (SFP)
●
1000BASE-SX
●
1000BASE-LX/LH
●
1000BASE-ZX
●
RMON I and II standards
●
SNMPv1, SNMPv2c, and SNMPv3
●
100BASE-X (SFP)
●
1000BASE-X (SFP)
●
1000BASE-SX
●
1000BASE-LX/LH
●
1000BASE-ZX
●
RMON I and II standards
●
SNMPv1, SNMPv2c, and SNMPv3
Table 6. Compliance Specifications
Description Specification
Standard safety certifications
●
UL to UL 60950-1
●
cUL to CAN/CSA C22.2 No. 60950-1
●
TUV/GS to EN 60950-1
●
CB to IEC 60950-1 with all country deviations
●
NOM (through partners)
●
CE Marking
Industrial safety certifications
●
UL 508
●
CSA C22.2 No. 142
Mechanical stability
●
Shock—20g (operational), 30g (nonoperational)
EMC interface immunity
●
IEC61000-4-2 [Criteria A—Class 2]
●
IEC61000-4-3/ENV50204 [Criteria A]
●
IEC61000-4-4 [Criteria A / Criteria B]
●
IEC61000-4-5 [Criteria B]
●
IEC61000-4-6 [Criteria A]
Standard electromagnetic
emissions certifications
●
FCC Part 15 Class A
●
EN 55022: 1998 (CISPR22)
●
EN 55024: 1998 (CISPR24)
●
VCCI Class A
●
AS/NZS 3548 Class A
●
CE
●
CNS 13438 Class A
●
MIC
Industrial electromagnetic
emissions certifications
●
EN 50081-2
●
EN 50082-2
●
EN 61131-2
●
EN 61326-1
●
CISPR11
●
IEC 60533
Industry specifications
●
IEC 61850-3 (Substations)
●
IEEE1613 (Substations)
●
NEMA TS-2 (ITSs)
●
EN50155 (Railway)
●
ODVA Common Industrial Protocol
●
IEEE 1588v2
Hazardous locations
●
UL 1602 Class 1, Div 2 A-D
●
CSA 22.2 / 213 Class 1, Div 2 A-D
●
IEC 60079-15
●
EN 50021 – Class 1, Zone 2
Telco Common Language Equipment Identifier (CLEI) code
Warranty One year limited warranty
Service and Support
Comments to this Manuals