Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.2(3)
OL-14116-04
Caveats
CSCsl55450
Symptom: The Fabric Manager Server GUI displays "Finished searching the table. The search item
not found." This occurs when you select Inventory and then Zones to display the Member column,
then click the Find icon (binoculars). In the resulting window, you type a word that is not on the first
page and click 'find from start'. The main web page appears to refresh, but does not actually locate
anything.
If you search for an item that is not on the first page, an error message displays "Finished searching
the table. The Search item not found".
Workaround: None.
CSCsi43117
Symptom: CFS merge information does not include SNMP support.
Workaround: This will be included in a future Fabric Manager release.
Open Caveats
CSCsg49151
Symptom: If you bring up more than one link at a time between two VSANs that have overlapping
domains and at least one of the switches is SDV enabled, one link will become isolated. The other
links will come up, even though the domains are overlapping. In addition, the SDV virtual domains
will change, causing traffic disruption on all devices associated with their old value.
Workaround: Bring up multiple links between two switches one at a time. Verify that the first link
came up correctly before attempting to bring up the next link. If the first link fails to come up
because of a domain ID overlap, resolve the domain conflict and then try again to bring up the links.
CSCsi72048
Symptom: FCIP links may fail on an MDS 9216i switch that has compression set to auto when the
other end of the FCIP link is terminated by an IPS-8 module. You may see the following message in
the logs:
%IPS_SB_MGR-SLOT1-3-CRYPTO_FAILURE: Heartbeat failure in encryption engine (error
0x1)
%ETHPORT-5-IF_DOWN_SOFTWARE_FAILURE: Interface GigabitEthernet1/1 is down (Port
software failure)
%PORT-5-IF_DOWN_SOFTWARE_FAILURE: %$VSAN 1%$ Interface fcip99 is down (Port software
failure)
Workaround: If both ends of an FCIP link are not on an MPS-14/2 module, do not use mode 1 and
auto.
CSCsk43922
Symptom: A data path processor (DPP) might fail on an MDS switch running SSI Release 3.2(1)
on the SSM. The failure occurs after several days of running traffic when a misbehaving target sends
unexpected frames well after the response has already been received from the same target.
Workaround: None.