31
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.2(3)
OL-14116-04
Caveats
CSCsg19303
Symptom: Graceful shutdowns of ISLs are not supported for IVR traffic.
Workaround: Increase the FSPF cost on the link before it is shut down, so that traffic will flow
through an alternate path.
CSCsi66310
Symptom: The management port on MDS switches supports one user-configured IPv6 address, but
does not support autoconfiguration of an IPv6 address in Cisco SAN-OS Release 3.2(1).
Workaround: None.
CSCsj24904
Symptom: On a Gigabit Ethernet interface on an MDS MSM-18/4 module, shut the interface before
removing its IP address so that configuration changes on the interface can take effect. This applies
only to the Gigabit Ethernet ports in slot 1 of the MDS 9222i switch and the MDS 9216i switch.
Workaround: Always shut the interface using the shutdown command before removing the IP
address and making configuration changes.
CSCsj72666
Symptom: In certain conditions, an MDS switch may not be able to determine the FC4-type of
certain targets. This causes the targets to be listed in the hosts section during a Cisco SME tape group
or tape device configuration.
Workaround: Issue the discover scsi-target vsan vsan-id fcid fcid command to re-discover the
FC4-type of the targets. A Cisco SME tape group or tape device configuration will now list the
targets correctly.
CSCsk00953
Symptom: HP Blade Servers that are connected through an HP Virtual Connect (VC) FC module to
a Cisco Fabric Switch for HP c-Class BladeSystem using NPIV lose access to LUNs when load
balancing on the VC module is switched from 16:1 to 8:1. When the load balancing ratio is 16:1, all
servers connect through interface ext1. When the ratio is 8:1, servers 1 and 3 connect through ext1,
servers 2 and 4 connect through ext2, and so on. Servers on ext2 are not affected by the switchover.
In addition, packets might get dropped when the switchover occurs.
Workaround: None.
CSCsk06186
Symptom: In rare situations, on an MDS 9513 director switch, an upgrade fails when a standby
supervisor does not come up to a state that the installer recognizes. As a result, the standby
supervisor is reloaded to recover and the system runs the older configuration version.
Workaround: Perform the upgrade again.
CSCsk35725
Symptom: Fabric Manager takes 2 to 3 minutes to bring up the DMM job creation wizard in a setup
with 25 switches, 400 enclosures, and 2400 entries in the name server.
Workaround: None.
CSCsk35951
Symptom: In a configuration with a PortChannel with FCIP members and write acceleration in use,
if IVR NAT is enabled on one end of the PortChannel and not enabled on the other end, then traffic
over the FCIP tunnel might fail.
Workaround: Enable IVR NAT on both ends of the PortChannel or disable it on both ends.