Cisco UCS C240 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
TECHNICAL SPECIFICATIONS
57
The general power specifications for the C240 M3 LFF server 650 W power supply are listed in Table 31.
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx
Power supply efficiency CSCI Platinum
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
Table 32 UCS C240 M3 LFF 650 W Power Supply Specifications
Description Specification
AC input voltage 90 to 264 VAC self-ranging,
100 to 120 VAC nominal
200 to 240 VAC nominal
AC input frequency Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)
Maximum AC input current 7.6 A maximum @ 100 VAC
3.65 A maximum @ 208 VAC
Maximum AC inrush current 11 A peak at 35° C, 208 VAC
Maximum output power for the
power supply
650 W
Power supply output voltage Main power: 12 VDC
Standby power: 12 VDC
Power supply efficiency CSCI Platinum
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
Table 31 UCS C240 M3 LFF 450 W Power Supply Specifications (continued)
Description Specification