Configuring Voice Ports
Analog Voice Ports Configuration Task List
VC-51
Cisco IOS Voice, Video, and Fax Configuration Guide
Step 4
Router(config)# pots disconnect-supervision {osi |
reversal}
(Optional) Specifies how the router notifies the
connected telephones, fax machines, or modems
when the calling party has disconnect. The keywords
are as follows:
osi—(open switching interval) Specifies the
duration for which DC voltage applied between
tip and ring conductors of a telephone port is
removed.
reversal—Specifies the polarity reversal of the
tip and ring conductors of a telephone port.
The default depends on the country chosen in the
pots country command.
Step 5
Router(config)# pots encoding {alaw | ulaw}
(Optional) Specifies the pulse code modulation
(PCM) encoding scheme for telephones, fax
machines, or modems connected to a Cisco 800
series router. The keywords are as follows:
alaw—Specifies the ITU-T PCM encoding
scheme used to represent analog voice samples
as digital values.
ulaw—Specifies the North American PCM
encoding scheme used to represent analog voice
samples as digital values.
The default depends on the country chosen in the
pots country command.
Step 6
Router(config)# pots tone-source {local | remote}
(Optional) Specifies the source of dial, ringback,
and busy tones for telephones, fax machines, or
modems connected to a Cisco 800 series router. The
keywords are as follows:
local—(default) Specifies that the router
supplies the tones.
remote—Specifies that the telephone switch
supplies the tones.
Step 7
Router(config)# pots ringing-freq {20Hz | 25Hz |
50Hz}
(Optional) Specifies the frequency at which
telephones, fax machines, or modems connected to a
Cisco 800 series router ring. The keywords are as
follows:
20Hz—Indicates that connected devices ring at
20 Hz.
25Hz—Indicates that connected devices ring at
25 Hz.
50Hz—Indicates that connected devices ring at
50 Hz.
The default depends on the country chosen in the
pots country command.