Cisco MGC Node Manager Installation Guide Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 46
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
1-4
Cisco Media Gateway Controller Node Manager Installation Guide
OL-14272-02
Chapter 1 Installation Overview and Planning
Determine Your Hardware Requirements
Cisco VSPT (only) installed on a Cisco PGW 2200 Softswitch host machine
Cisco MNM installed on a network management server and Cisco VSPT installed on a separate
server
Caution Cisco MNM is not supported on a Cisco PGW 2200 Softswitch host machine.
Hardware Requirements
The Cisco MNM hardware requirements for various network sizes are described in Table 1-1. Except in
a very small network, each operator requires an X terminal workstation.
Note Disk drive requirements are based on the number of drives. The Cisco MNM host machine requires the
minimum number of drives indicated in
Table 1-1. These are recommendations to aid you in planning.
The total amount of disk space required depends on many factors, such as the amount of alarm and
performance data collected.
Disk Drives and Database Storage
In a medium or large network, using multiple disk drives to store databases helps alleviate I/O
bottlenecks and improves software performance. If you are using multiple disk drives for database
storage, or you expect to generate large database files, use raw partitions, as described in the Cisco
Element Management Framework Installation and Administration Guide at
http://www.cisco.com/en/US/docs/net_mgmt/element_manager_system/3.2_service_pack_7/installatio
n/guide/3_2p7adm.pdf
Note If you are using Unix File System (UFS) partitions, installing more than one drive for database storage
does not improve performance because the databases cannot span multiple partitions.
Ta b l e 1-1 Hardware Requirements for Cisco MNM Host Machine(s)
Cisco PGW 2200 Softswitch
Number, Network Size
Small Network, 1-3 Operators,
1-3 Pairs of
Cisco
PGW 2200 Softswitch
Medium Network
, 4-6 Operators, 6-10 Pairs of
Cisco
PGW 2200 Softswitch
Large Network, 7-10
Operators, 11-20 Pairs of
Cisco
PGW 2200 Softswitch
RAM (GB) 8 8 16
Swap (GB) 8 8 16
Disk drives 2 x 73 G
1
1. Two-drive machines work for smaller networks that have less traffic and fewer operators. Response time to operator commands slows down as the
network grows and additional operators are added.
4 x 73 G RAID 0 (maximum
performance)
or
4 x 73 G RAID 0+1 (for
stability)
4 x 73 G RAID 0 (maximum
performance)
or
4 x 73 G RAID 0+1 (for
stability)
CPU T2000—4 Core T2000—4 Core T2000—8 Core
Page view 9