3-11
Cisco ONS 15216 EDFA2 Operations Guide
78-13908-02
Chapter 3 Installation
Communications
An RS-232 link to the ONS 15216 EDFA2 is established. The user can now provision the ONS 15216
EDFA2. For provisioning instructions, see Chapter 4, “Provisioning.”
Remote Communication Setup
This section describes the procedure for establishing a remote dial-up connection to the ONS 15216
EDFA2. ONS 15216 EDFA2 remote communication requires two US Robotics 56K Fax modems set up
to send data over a two-wire dial-up telephone line. (See Figure 3-7.)
This section assumes the use of the US Robotics 56K Fax modem V.90. Other modem types may require
different settings to establish a remote dial-up connection. The user should review their modem
documentation to ensure compatibility between US Robotics and other vendor modem types.
Figure 3-7 Remote Communication
Remote Communication Component Requirements
Table 3-6 lists the components required to communicate remotely with a ONS 15216 EDFA2. Table 3-6
is divided into two sections: Remote Site and Local Site. The Remote Site section lists components
needed at the site that contains the ONS 15216 EDFA2 and the Local Site section lists components
needed at the site where the user is located.
Table 3-5 User Levels and Passwords
User Level Password Description
monitor ro Can only display a few status parameters.
operator rw Performs the day-to-day operations on the equipment.
CISCO15 by default, there is no
password (press Enter)
Administrator who is responsible for configuring the ONS
15216 EDFA2 and performing software upgrades.
root root Super user who operates special commands that are reserved
for people who know the architecture of the ONS 15216
EDFA2.
Modem
Workstation
Modem
PSTN Dial up
Phone line
71458
Network
Cisco ONS 15216
EDFA2
Table 3-6 ONS 15216 EDFA2 Communication Components
Component Notes
Remote Site
1 ONS 15216 EDFA2
Page view 36
1 ... 36 37 38 ... 112

Comments to this Manuals