5-24
Cisco ONS 15216 EDFA2 Operations Guide
78-13908-02
Chapter 5 SNMP MIB Installation and Configuration
Retrieving Information
InPowerdBm
Command: snmp attribute get local cerent15216EdfaInPowerdBm
Syntax: snmp attribute get local cerent15216EdfaInPowerdBm
Description: Displays the ONS 15216 EDFA2 loss of input power value in dBm.
The following command displays input power value and other status information:
• snmp row display local cerent15216EdfaOverallStatusGroup command
Refer to Table 5-8 for information about all of the parameters in the
cerent15216EdfaOverallStatusGroup Table.
Loss of Input Power Alarm Threshold
LOSThreshold
Command: snmp attribute get local cerent15216EdfaLOSThreshold
Syntax: snmp attribute get local cerent15216EdfaLOSThreshold
Description: Displays the loss of input power alarm threshold.
The following commands display the loss of input power alarm threshold and other laser power and
temperature data:
• snmp row display local cerent15216EdfaCfgGroup command
The cerent15216EdfaLOSThreshold attribute in the cerent15216EdfaCfgGroup display command shows
the loss of input power alarm threshold (Example 5-12).
For information about all of the parameters in the cerent15216EdfaCfgGroup table, refer to Table 5-6.
Loss of Input Power Alarm Hysteresis
Command: snmp attribute get local cerent15216EdfaLOSHysteresis
Syntax: snmp attribute get local cerent15216EdfaLOSHysteresis
Description: Displays the loss of input power value.
The following commands display the loss of input power hysteresis value and other laser power and
temperature data:
• snmp row display local cerent15216EdfaCfgGroup command
The cerent15216EdfaLOSHysterisis attribute in the cerent15216EdfaCfgGroup display command shows
the loss of input power alarm threshold (Example 5-12). For information about all of the parameters in
in the cerent15216EdfaCfgGroup table, refer to Table 5-6.