5-22
Cisco ONS 15216 EDFA2 Operations Guide
78-13908-02
Chapter 5 SNMP MIB Installation and Configuration
Retrieving Information
CtmpMax
Command: snmp attribute get local cerent15216EdfaCtmpMax
Syntax: snmp attribute get local cerent15216EdfaCtmpMax
Description: This command displays maximum case temperature alarm threshold.
The following commands display case temperature alarm threshold and other temperature data:
snmp row display local cerent15216EdfaCfgGroup command
Example 5-12 cerent15216EdfaCfgGroup Display Command
hostname:ONS15216 EDFA2> snmp row display local cerent15216EdfaCfgGroup
CLASS cerent15216Edfa--MIB.cerent15216EdfaCfgGroup ::=
{
cerent15216EdfaCfgSaved = true;
cerent15216EdfaLpoutSetpoint = 1000;
cerent15216EdfaLpoutDeviation = 200;
cerent15216EdfaLpoutHysteresis = 100;
cerent15216EdfaLOSThreshold = -2400;
cerent15216EdfaLOSHysteresis = 100;
cerent15216EdfaCtmpMin = 5;
cerent15216EdfaCtmpMinHysteresis = 1;
cerent15216EdfaCtmpMax = 65;
cerent15216EdfaCtmpMaxHysteresis = 1;
};
Refer to Table 5-8 for information about all of the parameters in cerent15216EdfaStatusGroup.
Case Temperature Alarm Hysteresis
CtmpMaxHysteresis
Command: snmp attribute get local cerent15216EdfaCtmpMaxHysteresis
Syntax: snmp attribute get local cerent15216EdfaCtmpMaxHysteresis
Description: Displays maximum case temperature alarm hysteresis.
The cerent15216EdfaCtmpMaxHysteresis attribute in the cerent15216EdfaCfgGroup display command
shows the maximum case hysteresis temperature alarm threshold (Example 5-12). Refer to Table 5-6 for
information about all of the parameters in cerent15216EdfaCfgGroup.
CtmpMinHysteresis
Command: snmp attribute get local cerent15216EdfaCtmpMinHysteresis
Syntax: snmp attribute get local cerent15216EdfaCtmpMinHysteresis
Description: Displays the minimum case hysteresis temperature alarm threshold.
The following commands display case temperature alarm hysteresis and other data:
snmp row display local cerent15216EdfaCfgGroup command
The cerent15216EdfaCfgGroup command is shown in Example 5-12. For information about all of the
parameters in the cerent15216EdfaCfgGroup table, seeTable 5-6.