8
Cisco 6260 Quad-Port Flexi ATU-C to Octal-Port DMT ATU-C Line Card Conversion Procedures
OL-0991-01
Quad-Port Flexi ATU-C to Octal-Port DMT ATU-C Line Card Conversion Procedures
Quad-Port Flexi ATU-C to Octal-Port DMT ATU-C Line Card
Conversion Procedures
The following sections detail the procedures for converting your Cisco 6260 system from 4xflexis
to 8xDMTs.
Warning
Only trained and qualified personnel should be allowed to install, replace, or service
this equipment.
Note Before installing and cabling the equipment, be aware of standard safety practices and the hazards
involved in working with electrical circuitry to prevent accidents. See the “General Safety
Precautions” section on page 3 for all cautions and warnings that are necessary to ensure a safe and
hazard-free installation.
To see translations of the warnings that appear in this publication, refer to Regulatory Compliance
and Safety Information for the Cisco 6260 System.
Conversion Checklist
When you convert your system from 4xflexis to 8xDMTs, be sure that you follow the conversion
procedures in the proper sequence. Table 2 is a checklist of the conversion steps in the order in which
they should occur. Detailed conversion instructions are located in the sections following Table 2.
Caution Proper ESD protection is required whenever you handle Cisco equipment. Installation and
maintenance personnel should be properly grounded using ground straps to eliminate the risk of ESD
damage to the equipment. Cards are subject to ESD damage whenever they are removed from
the chassis.
See the “Preventing Electrostatic Discharge Damage” section on page 7 for ESD information.
Table 2 Conversion Procedure Checklist
Check Conversion Step
1. Upgrade IOS.
2. Remove the power.
3. Measure the rack space and prepare the rack.
4. Stabilize the rack.
5. Install the POTS splitter, as necessary.
6. Verify the Cisco 6260 cabling.
7. Remove the 4xflexis.
8. Install the 8xDMTs.
9. Verify the correct fuses.