5-14
Cisco AS5800 Operations, Administration, Maintenance, and Provisioning Guide
DOC-7810814=
Chapter 5 Maintenance
Replacement Procedures
Note Power supplies are numbered 1 and 2 from left to right in the power shelf.
Step 3 Lift the metal spring-clip in the center of the ejector lever to release the lock. (The power supplies are
secured by self-locking ejector levers. (See Figure 5-11.)
Figure 5-11 Removing and Replacing a Power Supply
Step 4
Apply downward pressure to the ejector lever to disconnect the power supply from the power backplane.
Step 5 Grasp the power supply handle and pull the power supply halfway out of the bay. Then with your other
hand under the power supply to support it, pull the power supply completely out of the bay.
To replace the power supply, follow these steps:
Step 1 Slide the power supply into the power supply bay. Push the power supply fully into the power shelf until
the front is flush against the power shelf frame. To prevent damage to the backplane connector, do not
jam the power supply into the bay.
Step 2 Push the self-locking ejector lever upward until the metal spring-clip locks into place (listen for the
click). (See Figure 5-11.)
This completes the power supply replacement procedure.