8 Troubleshoot Startup Problems
SCE 1000 Operational Status
The following table lists the operational states of the SCE 1000. The Status LED on the SCE 1000 Front Panel reflects
the current SCE 1000 operational status. The operational status can be displayed using CLI command show system
operation-status.
Table 8-1 SCE 1000 Operational States
SCE 1000
Operational
Status
Description Status LED State
Booting Initial state after reset Orange
Operational SCE 1000 becomes operational after completing the following
process:
Boot is completed
Power self-tests are completed without failure
Platform configuration is applied
Flashing green
Warning SCE 1000 is fully operational (as above) but one of the
following occurred:
Line ports (GBE ports) to the link are down
Management port link is down
Temperature raised above threshold
Voltage not in required range
Fans problem
Power supply problem
Insufficient space on the disk
Note: If the condition that caused the SCE 1000 to be in
Warning state is resolved (for example, link is up) the SCE
1000 reverts to Operational state.
Flashing orange
Failure System is in Failure state after Boot due to one of the following
conditions:
Power on test failure.
Three abnormal reboots in less than 20 minutes
Platform configured to enter Failure mode consequent to
failure-induced reboot (this is configurable using CLI
command).
Note: Depending on the cause of failure, the management
interface and the platform configuration may or may not be
active/available.
Red