30
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.2(3)
OL-14116-04
Caveats
CSCsk54591
Symptom: In rare cases, if two or more catastrophic exceptions affecting the MDS arbiter occur in
quick succession, it is possible that an MDS 9500 Series switch will completely reset.
Workaround: None.
CSCsl39215
Symptom: The CIM server stops. This occurs after creating a subscription using the same filter and
handler.
Workaround: Reload the switch.
CSCsl71227
Symptom: Using Fabric Manager Release 3.2(2), if you have an enclosure with multiple ports and
you then use the Data Migration Wizard to create a job with that enclosure as the existing storage
but don't select all the storage ports in the enclosure, an error is displayed in the creation wizard.
Workaround: Put the ports you plan to use as the existing storage in the migration into a separate
enclosure, and use that enclosure in the wizard selection.
CSCsl73987
Symptom: In rare instances, when a SCSI I/O is in progress in Cisco SME and it is aborted by the
host, the Cisco SME interface may fail and a reset may occur.
Workaround: This issue is resolved.
CSCin95789
Symptom: When you configure Cisco Traffic Analyzer to capture traffic on one or more interfaces
on a Windows platform, the configuration web page might not show that the interface has been
selected for traffic capture even though traffic capture on that interface is enabled.
Workaround: Check the logs to clarify that the correct interface has been selected.
CSCse31881
Symptom: If there are IP over Fibre Channel (IPFC) interfaces configured on an SSM, you might
experience issues if you downgrade from SAN-OS Release 3.x to Release 2.x.
Workaround: Before downgrading, remove the IPFC interface on the module and then recreate the
IPFC interface after the downgrade is complete.
CSCse47687
Symptom: If IP ACLs are applied to any IP Storage Gigabit Ethernet port, implicit deny does not
take effect.
Workaround: Configure explicit deny on the port.
CSCsg19148
Symptom: Time zone changes that are executed on an MDS switch do not take effect on the 12-port,
24-port, and 48 port 1-Gbps/2-Gbps/4-Gbps Fibre Channel modules, and on the 4-port 10-Gbps
module. This issue occurs in SAN-OS Releases 3.0(1), 3.0(2), 3.0(2a), and 3.0(3).
Time zone changes that are executed on an MDS switch do not take effect on the 16-port or 32-port
1-Gbps/2-Gbps module, on the 4-port or 8-port Gigabit Ethernet IP services module, the MPS-14/2
module, and on the SSM. This issue occurs in SAN-OS Release 3.0(3).
This issue has no effect on functionality. However, debug messages and syslogs from the MDS
switching modules have incorrect timestamps if the time zone is configured on an MDS switch.
Workaround: None.