Page view 108
3-45
Catalyst 2955 Hardware Installation Guide
78-14944-03
Chapter 3 Installation
Connecting the Switch to the Power Converter
Step 9 Connect the red wire to the positive pole of the DC power source, and connect the
black wire to the return pole. Ensure that each pole has a current-limiting-type
fuse rated to at least 600 VAC/DC ( such as the KLKD Midget fuse).
Step 10 Set the input voltage selector on the power converter to 230 V.
Figure 3-21 shows the completed wiring for the power converter and a
Catalyst 2955 switch.
Figure 3-21 The Power Converter Connected to the Catalyst 2955 Switch
and a DC Power Source
1 Power and relay connector 4 To earth ground
2 4 inches of thermal spacing 5 DC input wires
3 DC output wires 6 Switch functional ground connection