Catalyst 2955 Hardware Installation Guide
78-14944-03
Chapter 4 Installation in a Hazardous Environment
Verifying Switch Operation
Wiring the DC Power Source
Warning
Only trained and qualified personnel should be allowed to install or replace this
equipment.
Statement 49
Warning
In switch installations in a hazardous location, the DC power source could be
located away from the vicinity of the switch. be sure that power is removed and
power cannot be accidentally be turned on or the area is nonhazardous before
proceeding.
Statement 1059
Warning
When you disconnect the power and relay connector with power applied to the
switch, an electrical arc can occur. This could cause an explosion in hazardous
area installations. Be sure that power is removed from the switch and cannot
be accidentally be turned on, or verify that the area is nonhazardous before
proceeding.
Failure to securely tighten the power and relay connector captive screws can
result in an electrical arc if the connector is accidentally removed.
Statement
1058
Warning
Connect the unit only to DC power source that complies with the safety
extra-low voltage (SELV) requirements in IEC 60950 based safety standards.
Statement 1033
Caution The AC/DC power converter (PWR-2955-AC=) can only be used in a
nonhazardous location installation.
Caution You must connect the Catalyst 2955 switch only to a DC-input power source that
has an input supply voltage from 18 to 32 VDC. If the supply voltage is not in this
range, the switch might not operate properly or might be damaged.