Page view 114
3-51
Catalyst 2955 Hardware Installation Guide
78-14944-03
Chapter 3 Installation
Wiring the External Alarm Device Relays
Figure 3-25 shows the completed wiring for two power supplies and two external
alarm devices on a power and relay connector.
Figure 3-25 Completed Connections for Two External Alarm Devices on the
Power and Relay Connector
1 Power supply A positive
connection
5 External device 2, relay wire B
connection
2 Power supply A return
connection
6 External device 1, relay wire B
connection
3 External device 1, relay wire A
connection
7 Power supply B return
connection
4 External device 2, relay wire A
connection
8 Power supply B positive
connection