Chapter 3 Initially Configuring the ATM Switch Router
Configuring Online Diagnostics (Catalyst 8540 MSR)
3-21
ATM Switch Router Software Configuration Guide
78-6277-03, Cisco IOS Release 12.0(13)W5(19)
Examples
The following example shows how to enable all online diagnostic tests:
Switch(config)# diag online
ONLINE-DIAG: Enabling all Online Diagnostics tests
The following example shows how to change the frequency of the access test to 20 seconds:
Switch(config)# diag online access freq 20
ONLINE-DIAG: Online Access Test Frequency set to 20 sec
Displaying the Online Diagnostics Configuration and Results (Catalyst 8540 MSR)
To display the online diagnostics configuration and results, use the following EXEC command:
Examples
The following example shows how to display detailed access test configuration and results:
Switch# show diag online details access
======== Online Access Test Details ========
Current Test Status : Test is Enabled
Current Frequency of Access Test : 20 seconds
Slot Card-Type Iteration Success Failure Last Failure
---- ---------- ---------- ------- ------- ------------
0/* Super Cam 42998 42998 0 ----
0/0 8T1 IMA PAM 42998 42998 0 ----
0/1 8E1 IMA PAM 42998 42998 0 ----
2/* ARM PAM 42998 42998 0 ----
3/* ETHERNET PAM 42998 42998 0 ----
5/* Switch Card 42998 42998 0 ----
5/0 Feature Card 42998 42998 0 ----
7/* Switch Card 42998 42998 0 ----
7/0 Feature Card 42998 42998 0 ----
9/* OC48c PAM 42998 42998 0 ----
10/* OCM Board 42998 42998 0 ----
10/0 QUAD 622 Generi 42998 42998 0 ----
======== Online Access Test Details End ========
diag online snake timer [seconds] Specifies the time interval for the snake test. The
default interval is 60 seconds.
no diag online [access | oir | snake] Disables the online diagnostic tests.
debug diag online [access | oir | snake] Enables debugging of online diagnostic tests.
no debug diag online [access | oir | snake] Disables debugging of online diagnostic tests.
Command Purpose
Command Purpose
show diag online [details | status][access | oir |
snake]
Displays information about the online
diagnostics test configuration and the test results.
Comments to this Manuals