2-39
Cisco MGX 8230 Edge Concentrator Installation and Configuration
Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001
Chapter 2 Module and Service Descriptions
Frame Relay Service Modules
• For the MGX-SCSI2-2HSSI back card, see Figure 2-22 on page 2-43.
• For the MGX-FRSM-HS1/B front card, see Figure 2-21 on page 2-42.
• For the multifunction MGX-12IN1-S4 back card, see Figure 2-23 on page 2-44. This back card
supports four V.35 or four X.21 ports.
LED Indicators
Table 2-8 and Table 2-9 describe the FRSM T1/E1 LED faceplate indicators for both the FRSM-HS1/B
and the FRSM-HS2.
MGX-FRSM-HS1/B Cabling
The cable models come from the Cisco 12-in-1 series of cables. (See Table 2-10.) Each cable can have
a male or female connector at the far end. Also, the available clock sources depend on the mode. In DTE
mode, the clock source is either line or ST (ST is a wire in the cable). For DCE, the clock source is the
front card.
See Table 2-11 for the relationship between cabling and modes and Table 2-12 for part numbers.
Table 2-8 Card Level LED Indicators for the FRSM-HS1/B and the FRSM-HS2
Type of LED Color Meaning
ACT LED Green Active
STBY LED Yellow Standby
FAIL LED Red Fail
Table 2-9 Line Level LED Indicators for the FRSM-HS1/B and the FRSM-HS2
Type of LED Color Meaning
Individual Port LEDs Green Active and OK
Red Active and Local Alarm
Yellow Active and Remote Alarm
Table 2-10 12IN1-S4 Back Card Cable Types
Cable Type X.21 V.35
DCE X.21 DCE V.35 DCE
DTE X.21 DTE V.35 DTE
Table 2-11 Cabling and Clock Sources for the MGX-FRSM-HS1/B
Mode Type of Cable Clock Source Mode of Far End
DTE DTE line DCE (male or female connector at far
end)
Comments to this Manuals