Page view 72
6-5
Cisco 7304 Router Modular Services Card and Shared Port Adapter Hardware Installation Guide
OL-4681-01
Chapter 6 Installing and Removing a Shared Port Adapter
Checking the Installation
Note A Fast Ethernet interface is used in the following examples for illustrative purposes.
The following sample display shows the events logged by the system as an MSC with a Fast Ethernet
SPA was removed from module slot 4 in the router. In this example, interface 0 (interface 4/0/0) on the
FastEthernet SPA was up and active when the MSC was removed from the router. Note that the system
logs that the MSC card was removed from slot 4 and that interface 4/0/0 is changed to down.
Router#
00:06:17:%WS_ALARM-6-INFO:ASSERT CRITICAL slot 4 Active Card Removed OIR Alarm
00:06:17:%OIR-6-REMCARD:Card removed from slot 4, interfaces disabled
00:06:18:%LINEPROTO-5-UPDOWN:Line protocol on Interface FastEthernet4/0/0, changed state
to down
When you reinsert the MSC with the installed SPA, the system automatically brings up the interface that
was changed to down when the MSC was removed.
Router#
00:07:29:%OIR-6-INSCARD:Card inserted in slot 4, interfaces administratively shut down
00:07:32:%WS_ALARM-6-INFO:CLEAR CRITICAL slot 4 Active Card Removed OIR Alarm
00:07:35:%LINK-3-UPDOWN:Interface FastEthernet4/0/0, changed state to up
00:07:36:%LINEPROTO-5-UPDOWN:Line protocol on Interface FastEthernet4/0/0, changed state
to up
Use the following procedure to verify that the MSC is installed correctly:
Step 1 Observe the console display messages and verify that the system discovers the MSC, while the system
reinitializes each interface, as follows:
If you installed a new MSC, the STATUS LED should be green (on). The system should recognize
all new interfaces but leave them configured as administratively down.
If you replaced an MSC, the STATUS LED should be green (on). The system should recognize each
interface and places each interface in the state that it was previously in before the MSC was
removed.
Step 2 Verify that the STATUS LED on the SPA goes on (is green) and remains on after the reinitialization is
complete. If the STATUS LED remains on, proceed to Step 5. If the STATUS LED does not remain on,
proceed to Step 3.
Step 3 If the STATUS LED on the SPA fails to go on, the SPA or the MSC might not have a compatible FPD
image or the SPA or MSC might not be fully seated even if the SPA locking captive installation screws
are locked. When a SPA is not recognized, the SPA STATUS LED is off. If this occurs in your network,
do the following:
a. Check for system messages indicating an FPD incompatibility or enter the show hw-module
subslot fpd command to ensure the FPD image on the SPA is compatible with the running Cisco
IOS. If an incompatibility exists, an FPD image package file must be downloaded from the Software
Center on Cisco.com and an FPD upgrade must be performed. For information on performing this
upgrade, see theUpgrading Field-Programmable Devices” chapter of the Cisco 7304 Modular
Services Card and Shared Port Adapter Software Configuration Guide. If the FPD is proven to be
compatible or you are unable to perform the verification steps, proceed with the following steps:
b. Remove the SPA from the MSC.
c. Inspect the SPA. Verify there are no bent pins or parts and that there is nothing lodged in the two
devices that could prevent a good connection.