Chapter 3 Installation
Connecting the Switch to the Power Converter
3-44
Catalyst 2955 Hardware Installation Guide
78-14944-03
Figure 3-20 AC/DC Power Input Terminal Block Wire Connections to a DC
Source
Warning
An exposed wire lead from a DC-input power source can conduct harmful levels
of electricity. Be sure that no exposed portion of the DC-input power source
wire extends from the power and relay connector.
Statement 122
Step 7 Insert the twisted-pair wire leads into the terminal block line and neutral
connections. Insert the black wire lead into the neutral wire connection and the
red wire lead into the line wire connection. Ensure that only wire with insulation
extends from the connectors. (See Figure 3-20.)
Step 8 Tighten the line and neutral terminal block screws.
1 Input voltage selector 3 Positive wire connection
2 Return wire connection (to DC
return)
4 Earth ground wire connection
104762
AC 115/230V 50-60Hz
N L
230V
4
2
1
3