Page view 70
2-29
Cisco AS5800 Operations, Administration, Maintenance, and Provisioning Guide
DOC-7810814=
Chapter 2 Commissioning
Task 3. Enabling the T3/T1 Controllers
Step 4 Verify that the controllers are up and no alarms or errors are detected. Error counters are recorded over
a 24-hour period in 15-minute intervals. In the display output, focus on the data in the current interval.
5800-NAS# show controller t3
T3 1/0/0 is up.
Applique type is Channelized T3
No alarms detected.
FEAC code received: No code is being received
Framing is M23, Line Code is B3ZS, Clock Source is Internal
Data in current interval (201 seconds elapsed):
0 Line Code Violations, 0 P-bit Coding Violation
0 C-bit Coding Violation, 0 P-bit Err Secs
0 P-bit Severely Err Secs, 0 Severely Err Framing Secs
0 Unavailable Secs, 0 Line Errored Secs
0 C-bit Errored Secs, 0 C-bit Severely Errored Secs
Total Data (last 1 15 minute intervals):
30664 Line Code Violations, 49191 P-bit Coding Violation,
47967 C-bit Coding Violation, 0 P-bit Err Secs,
0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,
2 Unavailable Secs, 0 Line Errored Secs,
10 C-bit Errored Secs, 10 C-bit Severely Errored Secs
5800-NAS#
5800-NAS# show controller T1 1/0/0:4
T1 1/0/0:4 is up.
Applique type is Channelized T1
Cablelength is short
No alarms detected.
Framing is ESF, Line Code is AMI, Clock Source is Line.
Data in current interval (240 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Data in Interval 1:
0 Line Code Violations, 8 Path Code Violations
11 Slip Secs, 26 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 26 Unavail Secs
Total Data (last 1 15 minute intervals):
0 Line Code Violations, 8 Path Code Violations,
11 Slip Secs, 26 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 26 Unavail Secs
5800-NAS#
After each controller is correctly set up, clear the counters and look for ongoing line violations and
errors. To do this, enter the clear counters command followed by the show counters command:
clear counters t1 1/0/0:4
show counters t1 1/0/0:4
Step 5 In the display output, focus on the data in the current interval. Error counters stop increasing when the
controller is configured correctly.
Tips The clear counters command does not reset or bring down the controller. The T1 stays up.