6-9
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 6 ASH Commands
Configuration Commands
6.2.6 pdm busmode modify Command
Command pdm busmode modify
Syntax Description pdm busmode modify {simplex | duplex}
Modifies power bus mode to simplex (single power source–Bus A) or duplex (redundant power
source–Bus A and B).
6.2.7 pdm cfg threshold bus display Command
Command pdm cfg threshold bus display
Syntax Description pdm cfg threshold bus display
Displays the minimum and maximum allowable power bus DC voltage.
Example 6-5 pdm cfg threshold bus display Command
ash:hostname:ONS15216 EDFA2> pdm cfg threshold bus display
BUS Threshold Low = 40000(mV)
BUS Threshold High = 57000(mV)
6.2.8 pdm cfg threshold bus modify Command
Command pdm cfg threshold bus modify
Syntax Description pdm cfg threshold bus modify
Modifies minimum and maximum allowable power bus DC voltage.
Example 6-6 pdm cfg threshold bus modify Command
ash:hostname:ONS15216 EDFA2> pdm cfg threshold bus modify
BUS Threshold Low = 40000(mV)
40500
BUS Threshold High = 57000(mV)
6.2.9 gain gain display Command