9-10
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 9 TL1 Commands
TL1 Commands and Autonomous Messages
Table 9-10 ALW-MSG-ALL Syntax Description
Parameter Syntax Description
ntfncde Notification code of the alarm or event that is to be
allowed (maps to cerent15216EdfaAlarmPriority for
active alarms). A null maps to none of the codes, i.e.,
with a null, all existing ntfncde inhibitions are kept
unchanged. Possible values are:
CR Critical alarm.
MJ Major alarm.
MN Minor alarm.
NA No alarm.
CL Cleared alarm.
condtype Condition type of the alarm or event that is to be allowed.
(Maps to cerent15216EdfaLogEventID.) ALL maps to
all types. A null maps to none of the types, i.e., with a
null, all existing condtype inhibitions are kept
unchanged. Possible condtype and corresponding
conddescr (in quotes) are:
LOS “Loss of Signal” (input power) alarm
(cerent15216EdfaAlarmLpin).
GAIN “Gain Out of Range” alarm
(cerent15216EdfaAlarmGain).
LPOUT “Loss of Output Power” alarm
(cerent15216EdfaAlarmLpout).
CTMP “Case Temperature Out of Range” alarm
(cerent15216EdfaAlarmCtmp).
LCRNT1 “Excessive Pump1 Current” alarm
(cerent15216EdfaAlarmLcrnt1).
LCRNT2 “Excessive Pump2 Current” alarm
(cerent15216EdfaAlarmLcrnt2).
LTMP1 “Excessive Pump1 Temperature” alarm
(cerent15216EdfaAlarmLtmp1).
LTMP2 “Excessive Pump2 Temperature” alarm
(cerent15216EdfaAlarmLtmp2).
POWERBUSA “Power Bus A (voltage) Alarm”
(cerent15216EdfaAlarmPowerBusA).
POWERBUSB “Power Bus B (voltage) Alarm”
(cerent15216EdfaAlarmPowerBusB).
CTRLMODE1 “Pump1 Control Mode Changed”
(cerent15216EdfaControlMode for
cerent15216EdfaPumpCfgPumpNumber=1).
CTRLMODE2 “Pump2 Control Mode Changed”
(cerent15216EdfaControlMode for
cerent15216EdfaPumpCfgPumpNumber=2).