Manufacturer Mode
6.10 Manufacturer Mode
A manufacturer mode enable command is available. It raises the root access level to the fifth and
highest manufacturer level to allow undocumented commands that are used only for manufacturing
purposes.
Warning
Customers are strongly cautioned not to use this mode.
6.10.1 manufacturer restore defaults passwords Command
Command manufacturer restore defaults passwords
Syntax Description manufacturer restore defaults passwords
Restores the manufacturing factory default passwords to the ONS 15216 EDFA2.
Note If the password for the CISCO15 user is lost and there are not other users with read_write_admin access
level in the system, the password for CISCO15 can be reset by following the procedure in “Recover
Default Password” section on page 4-14.
6.10.2 manufacturer restore defaults all Command
Command manufacturer restore defaults all
Syntax Description manufacturer restore defaults all
Restores the manufacturing factory settings to the ONS 15216 EDFA2. The files on the flash file system
(FFS), the date and time, and the values of manufacturing calibration are not affected. This command
must be followed by the processor reset command to take effect.
Warning
This command resets the IP address, resets the hostname, deletes the user directory, reverts CISCO15
to the default password, and resets other parameters to restore the unit to its state as shipped from
manufacturing.