4-8
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 4 Provisioning Using ASH and SNMP
Set Alarm Thresholds
cerent15216Edfa
LOSHysteresis
Loss of
signal
(input
power)
hysteresis
Integer
(0 to 1000,
100
default)
Read-write Used to set the amount the input signal
must increase above the LOS Threshold
level before the alarm is cleared. This
attribute, in conjunction with the loss of
input signal alarm threshold, enables
efficient clearing of alarms. Set this
attribute at a value that is appropriate for
the application so that the alarm
condition will clear when input is stable.
Consult with the Cisco TAC to determine
the correct value for your application. As
a guideline, Cisco recommends setting
the value 1 dB above the LOS Threshold
value. With this setting, the module will
clear the alarm if it detects a signal level
of 1 dB above the current LOS Threshold
value. Valid entries are between 0 and
1000 and are in dB times 100. For
example, if the hysteresis required is 1
dB, the power alarm hysteresis is 100.
cerent15216Edfa
CtmpMin
Minimum
case
temperature
Integer
(–10 to 10,
–5 default)
Read-write Alarm notifies operations personnel if
the case temperature of the
ONS 15216 EDFA2 drops below a level
that impacts proper operation of the
optical network. The minimum case
temperature should be set at a value that
is appropriate for the intended
application and within product
specifications. Consult with the Cisco
TAC to determine the correct value for
your application. As a guideline, Cisco
recommends that minimum case
temperature be set at 1
°C. Valid entries
are between –10 and 10
°C.
cerent15216Edfa
CtmpMinHystere
sis
Minimum
case
temperature
hysteresis
Integer
(0 to 10,
1 default)
Read-write Used to set the amount that the case
temperature of the module must rise
above the minimum case temperature
alarm level before the alarm is cleared.
Set the hysteresis at a value that is
appropriate for the application so that the
alarm condition clears when the input is
stable. Consult with the Cisco TAC to
determine the correct value for your
application. As a guideline, Cisco
recommends that the hysteresis value be
set at 1
°C. Valid entries are between 0
and 10
°C. Setting this value to 0 disables
this option.
Table 4-1 Alarm Threshold Attribute Definitions (continued)
Attribute
Variable
Definition Syntax
Maximum
Access Description
Page view 55
1 ... 55 56 57 ... 280

Comments to this Manuals

No comments

VIAIR 380C Dual Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Für das Auto VIAIR 380C Dual.
Wir stellen 1 PDF-Handbücher VIAIR 380C Dual zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Bedienungsanleitung






Weitere Produkte und Handbücher für Für das Auto VIAIR

Modelle Dokumententyp
450C Dual Bedienungsanleitung   VIAIR 450C Dual User Manual, 8 Seiten
444C Dual Bedienungsanleitung   VIAIR 444C Dual User Manual, 8 Seiten
480C Dual Bedienungsanleitung   VIAIR 480C Dual User Manual, 8 Seiten
120 PSI Fast-Fill Bedienungsanleitung   VIAIR 120 PSI Fast-Fill User Manual [en] , 10 Seiten
200 PSI Fast-Fill Bedienungsanleitung   VIAIR 200 PSI Fast-Fill User Manual, 10 Seiten
150 PSI High-Flow Bedienungsanleitung   VIAIR 150 PSI High-Flow User Manual, 10 Seiten
200 PSI High-Flow Bedienungsanleitung   VIAIR 200 PSI High-Flow User Manual, 10 Seiten
Ultra-Light Duty OBA Bedienungsanleitung   VIAIR Ultra-Light Duty OBA User Manual, 8 Seiten
Quarter Duty OBA Bedienungsanleitung   VIAIR Quarter Duty OBA User Manual, 8 Seiten
Medium Duty OBA Bedienungsanleitung   VIAIR Medium Duty OBA User Manual, 12 Seiten
Heavy Duty OBA Bedienungsanleitung   VIAIR Heavy Duty OBA User Manual, 11 Seiten
Constant Duty OBA Bedienungsanleitung   VIAIR Constant Duty OBA User Manual, 11 Seiten
Super Duty OBA Bedienungsanleitung   VIAIR Super Duty OBA User Manual, 12 Seiten
Ultra Duty OBA Bedienungsanleitung   VIAIR Ultra Duty OBA User Manual, 11 Seiten
X'Treme Duty OBA Bedienungsanleitung   VIAIR X'Treme Duty OBA User Manual, 12 Seiten
Dual 380C OBA Bedienungsanleitung   VIAIR Dual 380C OBA User Manual, 12 Seiten
Dual 450C OBA Bedienungsanleitung   VIAIR Dual 450C OBA User Manual, 12 Seiten
Dual 400C OBA Bedienungsanleitung   VIAIR Dual 400C OBA User Manual, 12 Seiten
Dual 444C OBA Bedienungsanleitung   VIAIR Dual 444C OBA User Manual, 12 Seiten
High-Pressure (Universal) Bedienungsanleitung   VIAIR High-Pressure (Universal) User Manual, 8 Seiten