6-20
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 6 ASH Commands
SNMP Commands
cerent15216EdfaCtmpMin = 5;
cerent15216EdfaCtmpMinHysteresis = 1;
cerent15216EdfaCtmpMax = 65;
cerent15216EdfaCtmpMaxHysteresis = 1;
cerent15216EdfaCLEI = "CLEI";
cerent15216EdfaPowerBusMode = duplex;
cerent15216EdfaPowerBusDCVoltageMin = 480;
cerent15216EdfaPowerBusDCVoltageMax = 570;
6.6.8 snmp row get Command
Command snmp row get
Syntax Description snmp row get {IP_address | local} row_name index
Accesses a row. Use this command to obtain information to use with other commands. See
Example 6-20.
Example 6-20 snmp row get Command
ash:hostname:ONS15216 EDFA2> snmp row get local cerent15216EdfaCfgGroup
CfgSa Lpo Lpo Lpo LOST LOS C C Ct C CLEI PowerBu Pow Pow
false 0 200 100 -3000 100 -5 1 65 1 "CLEI" duplex 480 570
6.6.9 snmp row set Command
Command snmp row set
Syntax Description snmp row set {IP_address | local} row_name index
Sets data within a row. Use the snmp row display command first to view the contents of data within a
row. See Example 6-21.
Example 6-21 snmp row set Command
ash:hostname:ONS15216 EDFA2> snmp row set local cerent15216EdfaAlarmEntry 1
cerent15216EdfaAlarmEnableStatus disabled