Chapter 9 TL1 Commands
TL1 Commands and Autonomous Messages
9.7.10 ED-DWDM
Command ED-DWDM
Configures the ONS 15216 EDFA2 optical control parameters.
Syntax
ED-DWDM:[<tid>]:<aid>:<ctag>:::[PUMP1CTRLMODE=<pump1ctrlmode>],[PUMP1CTRLVALUE=<pump1ctrlv
alue>],[PUMP2CTRLMODE=<pump2ctrlmode>],[PUMP2CTRLVALUE=<pump2ctrlvalue>],[OVERALLGAIN=<gai
n>],[PREATT=<preatt>];
Example 9-12 ED-DWDM Command
Amp01:ONS15216 EDFA2> ED-DWDM:Amp01:ALL:123:::PUMP1CTRLMODE=GAINTEMP;
Table 9-17 ED-DWDM Syntax Description
Parameter Syntax Description
aid
1
ALL
1 and ALL have same input effect.
pump1ctrlmode,
pump2ctrlmode
Pump 1 or pump 2 control mode (maps to
cerent15216EdfaPumpCfgControlMode for the corresponding
pump). Generally, pump1ctrlmode and pump2ctrlmode must be
the same value. One exception is OPWR which is not valid for
pump 1 and can only be set for pump 2. Possible values are:
GAINTEMP Constant Gain Temperature Compensated mode (manufacturer
default) (cerent15216EdfaPumpCfgControlMode set to
constGainTempComp). If one pump is set to GAINTEMP, the
other pump automatically gets set to GAINTEMP also.
OPWR Constant Output Power mode
(cerent15216EdfaPumpCfgControlMode set to
constOutputPower). This is not a valid mode for pump 1. If
pump 2 is set to OPWR, pump 1 gets automatically set to PWR
with a value of 75 mW.
CRNT Constant Pump Current mode
(cerent15216EdfaPumpCfgControlMode set to constCurrent).
Must set pump 1 and pump 2 to this mode at the same time.
PWR Constant Pump Power mode
(cerent15216EdfaPumpCfgControlMode set to constPower).
Must set Pump 1 and Pump 2 to this mode at the same time.
IDLE
Pump is shut down (cerent15216EdfaPumpCfgControlMode
set to idle).