Chapter 4. Configuring InfiniBand with QLogic bridges 71
12.After you establish the bridge port to remote drive mapping, you need to establish another
mapping from SRP initiator to remote drive. On the bridge Web GUI main menu, click FCP
Device Discovery, and then Start. The remote drives that are mapped to the bridge ports
will show up in Discovered Devices (Figure 4-58).
Figure 4-58 Discovered Fibre Channel Target
13.Click Configure to designate a name for the device (Figure 4-59). This name will be used
later when mapping to an SRP Initiator.
Figure 4-59 Assign name to Fibre Channel Storage Device
14.After you designate a name, click Submit. The remote logical drive moves from
Discovered Devices to Configured Devices (Figure 4-60).
Figure 4-60 Configured Fibre Channel Target
15.Close the FCP Device Discovery window and click SRP map config on the GUI main
menu page. Here, you see your virtual HBAs listed. There will be two IOC headings, one
for each I/O Controller on the bridge module. These correspond to the two VFx Controllers
that you saw in device manager back in step 7:
If you want to map your target through IOC 1, click the Click To Add link under the
IOC 1 heading.
If you want to map your target through IOC 2, click the Click To Add link under the
IOC 2 heading.
16.Give the map a name and select a map type, then click Next.
There are two mapping types:
Explicit: In an explicit mapping, the host and target LUN numbers must be listed in the
mapping.
Direct: In a direct mapping, the host will see all remote drives that are visible to the
port WWNs without a specific LUN being identified.
You address explicit mapping first, and then direct mapping.