Cisco MGX 8950 Specifications Page 149

  • Download
  • Add to my manuals
  • Print
  • Page
    / 642
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 148
3-21
Cisco MGX 8850 (PXM1E/PXM45), Cisco MGX 8950, Cisco MGX 8830, and Cisco MGX 8880 Configuration Guide
Release 5.0.10, OL-3845-01 Rev. B0, August 16, 2004
Chapter 3 Provisioning PXM1E Communication Links
General PXM1E Configuration Procedures
General PXM1E Configuration Procedures
This section describes the following general procedures for configuring PXM1E card communications:
Configuring the Card Mode
Setting Up Lines
Configuring Inverse Multiplexing for ATM
Establishing Redundancy Between Two Lines with APS
Adding ATM Ports
Partitioning Port Resources Between Controllers
Selecting the Port Signaling Protocol
Defining Destination Addresses for Static Links
Assigning Static ATM Addresses to Destination Ports
Configuring ILMI on a Port
Configuring PXM1E Line Clock Sources
Verifying PNNI Communications
Provisioning and Managing SPVCs and SPVPs
Configuring and Managing a Connection to an IGX Feeder
Configuring the Card Mode
Enter the cnfcdmode <mode> command at the active PXM1E to configure the operational mode of all
lines on a PXM1E-16-T1E1 or PXM1E-COMBO card.
If you are configuring a PXM1E-16-T1E1 card, replace <mode> with one of the following:
1 to specify all lines as T1 lines
2 to specify all lines as E1 lines
If you are configuring a PXM1E-COMBO card, replace <mode> with one of the following:
3 to specify all T3/E3 lines as T3 lines
4 to specify all T3/E3 lines as E3 lines
Note You cannot change the card mode once the card has been configured. The cnfcdmode command does
not apply to the OC3c/SDH or higher speed lines. This command does not apply to PXM1E-8-T3E3
cards because the installed back card determines if all ports are T3 or E3.
In the following example, the user configures all lines on the PXM1E-COMBO back card
(MGX-T3E3-155) to operate as E3 lines.
Unknown.7.PXM.a > cnfcdmode 4
To verify the card’s operational mode, enter the dsplns command. The configured mode is displayed in
the Line Type column. For example, if the card mode is set to support T3 lines, the line type is
ds3cbitadm. If the card mode is set to support E3 lines, the line type is e3g832adm.
Page view 148
1 ... 148 149 150 ... 642

Comments to this Manuals