Cisco MGX 8950 Specifications Page 491

  • Download
  • Add to my manuals
  • Print
  • Page
    / 642
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 490
11-3
Cisco MGX 8850 (PXM1E/PXM45), Cisco MGX 8950, Cisco MGX 8830, and Cisco MGX 8880 Configuration Guide
Release 5.0.10, OL-3845-01 Rev. B0, August 16, 2004
Chapter 11 Viewing and Responding to Alarms
Displaying Alarm Reports in the CLI
Note PXM1E do not support switching alarms. Therefore, the commands in this section do not apply to
Cisco MGX 8850 (PXM1E) and Cisco MGX 8830 switches.
To display a report of all switching alarms, enter the following command:
M8850_LA.8.PXM.a > dspswalms
The following example is a sample report showing no switching alarms.
M8850_LA.8.PXM.a > dspswalms
XBAR SWITCHING FABRIC ALARMS SUMMARY
Xbar Core Alarm Xbar Port Alarm Xbar Slot B/W alarm
Slot No. Critical Major Minor Critical Major Minor Critical Major Minor
------- -------- ----- ----- -------- ----- ----- -------- ----- -----
01 0 0 0 0 0 0 0 0 0
02 0 0 0 0 0 0 0 0 0
03 0 0 0 0 0 0 0 0 0
04 0 0 0 0 0 0 0 0 0
05 0 0 0 0 0 0 0 0 0
06 0 0 0 0 0 0 0 0 0
07 -- -- -- -- -- -- -- -- --
08 0 0 0 0 0 0 0 0 0
09 -- -- -- -- -- -- -- -- --
10 0 0 0 0 0 0 0 0 0
11 0 0 0 0 0 0 0 0 0
12 0 0 0 0 0 0 0 0 0
13 -- -- -- -- -- -- -- -- --
14 -- -- -- -- -- -- -- -- --
To display additional information on switch alarms, enter the following commands:
dspXbarPlaneAlms
dspxbarslotbwalms
To display a report for xbar alarms, enter the following command:
M8850_NY.7.PXM.a > dspdevalms XBARCORE -pslot *
Page view 490
1 ... 490 491 492 ... 642

Comments to this Manuals