Cisco MGX 8950 Specifications Page 619

  • Download
  • Add to my manuals
  • Print
  • Page
    / 642
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 618
G-1
Cisco MGX 8850 (PXM1E/PXM45), Cisco MGX 8950, Cisco MGX 8830, and Cisco MGX 8880 Configuration Guide
Release 5.0.10, OL-3845-01 Rev. B0, August 16, 2004
APPENDIX
G
Reliability, Availability, and Serviceability
Both the PXM45 and the PXM1E support the following reliability, availability, and serviceability (RAS)
features:
Power On Self Test (POST)
Hardware Monitoring Module (HMM)
Online diagnostics
Offline diagnostics
Enhanced alarm reporting
The POST and HMM features are transparent to the user. However, the dsppostresults command can be
used to display the POST results. POSTs are a set of tests that run at boot-up time. POSTS cannot be
disabled.
Diagnostics
Diagnostics commands can be used to isolate or troubleshoot problems. The following procedure shows
the steps for identifying problems or failures:
Step 1 Observe card alarms.
MGX8850.7.PXM.a>dspndalms
Step 2 Observe hardware or diagnostic alarms and slot numbers
MGX8850.7.PXM.a>dspcdalms
Step 3 If there are hardware alarms, change card to appropriate slot .
MGX8850.7.PXM.a>cc slot
Step 4 Display alarms to identify the device.
MGX8850.7.PXM.a>dsphwalms
Step 5 Display errors on device.
MGX8850.7.PXM.a>dspdeverr device
Step 6 If there are diagnostic alarms, change card to appropriate slot
MGX8850.7.PXM.a>cc slot
Step 7 Display diagnostics results.